YASKAWA SGD7S-R70A20A023F40B Product Manual page 199

Table of Contents

Advertisement

Problem
Possible Cause
Absolute
Encoder
Position
Deviation
Error (The
position
that was
saved in the
host con-
Host Controller Multiturn
troller when
Data or Absolute Encoder
the power
Position Data Reading Error
was turned
OFF is dif-
ferent from
the posi-
tion when
the power
was next
turned ON.)
The P-OT/N-OT (Forward
Drive Prohibit or Reverse
Drive Prohibit) signal was
input.
Overtravel
Occurred
The P-OT/N-OT (Forward
Drive Prohibit or Reverse
Drive Prohibit) signal mal-
functioned.
5.2.7 Troubleshooting Based on the Operation and Conditions of the Servomotor
Confirmation
Check the error detec-
tion section of the host
controller.
Check to see if the host
controller is executing
data parity checks.
Check for noise interfer-
ence in the cable
between the SERVO-
PACK and the host con-
troller.
Check the external power
supply (+24 V) voltage for
the input signals.
Check the operating con-
dition of the overtravel
limit switches.
Check the wiring of the
overtravel limit switches.
Check the settings of the
overtravel input signal
allocations (Pn50A/
Pn50B).
Check for fluctuation in
the external power supply
(+24 V) voltage for the
input signals.
Check to see if the opera-
tion of the overtravel limit
switches is unstable.
Check the wiring of the
overtravel limit switches
(e.g., check for cable
damage and loose
screws).
5.2 FT41 Specification
Continued from previous page.
Correction
Reference
Correct the error detec-
tion section of the host
controller.
Perform parity checks
for the multiturn data or
absolute encoder posi-
tion data.
Implement counter-
measures against noise
and then perform parity
checks again for the
multiturn data or abso-
lute encoder position
data.
Correct the external
power supply (+24 V)
voltage for the input
signals.
Make sure that the
overtravel limit switches
operate correctly.
Correct the wiring of
*
the overtravel limit
switches.
Set the parameters to
*
correct values.
Eliminate fluctuation
from the external power
supply (+24 V) voltage
for the input signals.
Stabilize the operating
condition of the over-
travel limit switches.
Correct the wiring of
the overtravel limit
switches.
Continued on next page.
5
5-111

Advertisement