6.2 FT40 Specification

6.2.1 List of Servo Parameters
6.2

FT40 Specification

6.2.1
List of Servo Parameters
The following table lists the parameters.
Note: Do not change the following parameters from their default settings.
Parameter
No.
Pn000
6-4
• Reserved parameter
• Parameters not given in this manual
• Parameters that are not valid for the Servomotor that you are using, as given in the parameter table
Name
Basic Function Selec-
2
tions 0
Rotation Direction Selection
Movement Direction Selection
0

n.
X
1

n.
X
Reserved parameter (Do not change.)

n.
X
Reserved parameter (Do not change.)
Rotary/Linear Servomotor Startup Selection When Encoder Is Not Connected
0

n.X
1
Setting
Setting
Default
Range
Unit
Setting
0000
to
h
0000
10B1
h
Use CCW as the forward direction.
Use the direction in which the linear encoder counts up as the forward direc-
tion.
Use CW as the forward direction. (Reverse Rotation Mode)
Use the direction in which the linear encoder counts down as the forward
direction. (Reverse Movement Mode)
When an encoder is not connected, start as SERVOPACK for Rotary Servo-
motor.
When an encoder is not connected, start as SERVOPACK for Linear Servo-
motor.
Applicable
When
Motors
Enabled
fication
After
All
h
restart
Continued on next page.
Classi-
Refer-
ence
*1