Alarm Number:
Possible Cause
Alarm Name
The surrounding air
temperature around
the Servomotor is too
high.
A.860:
(Detected when a
The Servomotor load
Rotary Servomo-
is greater than the
tor, Absolute Lin-
rated load.
ear Encoder, or
Direct Drive Ser-
vomotor is con-
nected. However,
this alarm is not
A failure occurred in
detected for
the encoder.
SGMCS Servo-
motors with
Incremental
Encoders.)
(Detected at the
encoder end.)
A failure occurred in
the SERVOPACK.
The surrounding tem-
perature around the
Servomotor is too
high.
The motor load is
greater than the rated
load.
A.861:
Motor Over-
A failure occurred in
heated
the Serial Converter
Unit.
A failure occurred in
the SERVOPACK.
A.890:
A failure occurred in
Encoder Scale
the linear encoder.
Error
A.891:
A failure occurred in
Encoder Module
the linear encoder.
Error
Setting the origin of
the absolute linear
encoder failed
A.8A0:
because the motor
External Encoder
moved.
Error
A failure occurred in
the external encoder.
Confirmation
Reduce the surrounding
Measure the surround-
air temperature of the
ing air temperature
Servomotor to 40°C or
around the Servomotor.
less.
Operate the Servo Drive
Use the accumulated
so that the motor load
load ratio to check the
remains within the speci-
load.
fied range.
Turn the power supply to
the SERVOPACK OFF and
ON again. If an alarm still
occurs, the Servomotor or
–
absolute linear encoder
may be faulty. Replace the
Servomotor or absolute
linear encoder.
Turn the power supply to
the SERVOPACK OFF and
ON again. If an alarm still
–
occurs, the SERVOPACK
may be faulty. Replace the
SERVOPACK.
Measure the surround-
Reduce the surrounding
ing temperature around
air temperature of the
the Servomotor.
Servomotor to 40° or less.
Check the load with the
Operate the Servo Drive
accumulated load ratio
so that the motor load
on the Motion Monitor
remains within the speci-
Tab Page on the Sig-
fied range.
maWin+.
Turn the power supply to
the SERVOPACK OFF and
ON again. If an alarm still
occurs, the Serial Con-
–
verter Unit may be faulty.
Replace the Serial Con-
verter Unit.
Turn the power supply to
the SERVOPACK OFF and
ON again. If an alarm still
–
occurs, the SERVOPACK
may be faulty. Replace the
SERVOPACK.
The linear encoder may
–
be faulty. Replace the lin-
ear encoder.
Turn the power supply to
the SERVOPACK OFF and
ON again. If an alarm still
–
occurs, the linear encoder
may be faulty. Replace the
linear encoder.
Before you set the ori-
gin, use the fully-closed
The motor must be
feedback pulse counter
stopped while setting the
to confirm that the
origin position.
motor is not moving.
Replace the external
–
encoder.
5.1 FT40 Specification
5.1.3 Troubleshooting Alarms
Continued from previous page.
Correction
Reference
–
*1
–
–
–
*1
–
–
–
–
*1
–
Continued on next page.
5
5-23