6.3 FT41 Specification
6.3.1 List of Servo Parameters
Parameter
No.
Pn00A
Pn00B
6-76
Name
Application Function
2
Selections A
Motor Stopping Method for Group 2 Alarms
Apply the dynamic brake or coast the motor to a stop (use the stopping
0
method set in Pn001 = n.X).
Decelerate the motor to a stop using the torque set in Pn406 as the maximum
1
torque. Use the setting of Pn001 = n.X for the status after stopping.

n.
X
Decelerate the motor to a stop using the torque set in Pn406 as the maximum
2
torque and then let the motor coast.
Decelerate the motor to a stop using the deceleration time set in Pn30A. Use
3
the setting of Pn001 = n.X for the status after stopping.
Decelerate the motor to a stop using the deceleration time set in Pn30A and
4
then let the motor coast.
Stopping Method for Forced Stops
Apply the dynamic brake or coast the motor to a stop (use the stopping
0
method set in Pn001 = n.X).
Decelerate the motor to a stop using the torque set in Pn406 as the maximum
1
torque. Use the setting of Pn001 = n.X for the status after stopping.

n.
X
Decelerate the motor to a stop using the torque set in Pn406 as the maximum
2
torque and then let the motor coast.
Decelerate the motor to a stop using the deceleration time set in Pn30A. Use
3
the setting of Pn001 = n.X for the status after stopping.
Decelerate the motor to a stop using the deceleration time set in Pn30A and
4
then let the motor coast.

n.
X
Reserved parameter (Do not change.)

n.X
Reserved parameter (Do not change.)
Application Function
2
Selections B
Operator Parameter Display Selection

n.
X
0
Display only setup parameters.
1
Display all parameters.
Motor Stopping Method for Group 2 Alarms
0
Stop the motor by setting the speed reference to 0.

n.
X
Apply the dynamic brake or coast the motor to a stop (use the stopping
1
method set in Pn001 = n.X).
2
Set the stopping method with Pn00A = n.X.
Power Input Selection for Three-phase SERVOPACK

n.
X
0
Use a three-phase power supply input.
1
Use a three-phase power supply input as a single-phase power supply input.

n.X
Reserved parameter (Do not change.)
Setting
Setting
Default
Range
Unit
Setting
0000h to
0001h
0044h
0000h to
0000h
1121h
Continued from previous page.
Applicable
When
Classi-
Motors
Enabled
fication
After
All
Setup
restart
After
All
Setup
restart
Continued on next page.
Refer-
ence
*1
*1