6.3 FT41 Specification
6.3.3 Parameter Recording Table
Parameter
No.
Pn423
Pn424
Pn425
Pn426
Pn427
Pn440
Pn441
Pn442
Pn444
Pn445
Pn446
Pn447
Pn448
Pn449
Pn44A
Pn44C
Pn44D
Pn44E
Pn450
Pn451
Pn452
Pn456
Pn458
Pn459
Pn45A
Pn45B
Pn45C
Pn45D
6-128
Default Setting
0000h
50
100
0
0
0000h
100
2000
100
0
95
100
0
0
0
1000
300
0
0
100
100
15
0011h
500
1000
50
150
100
Continued from previous page.
Name
Speed Ripple Compensa-
tion Selections
Torque Limit at Main Circuit
Voltage Drop
Release Time for Torque
Limit at Main Circuit Voltage
Drop
Torque Feedforward Aver-
age Movement Time
Speed Ripple Compensa-
tion Enable Speed
Pressure Feedback Selec-
tion Switches
Reserved parameter
Pressure Feedback Control
1 Pressure Feedback Loop
Integral Time
Pressure Feedback Control
1 Pressure Feedback Loop
Feedforward
Reserved parameter
Reserved parameter
Pressure Feedback Loop
Deviation Overflow Level
Pressure Feedback Offset
Pressure Feedback Sensor
Gain
Pressure Feedback Filter
Pressure Feedback Enable
Level
Pressure Feedback Over-
flow Detection Level
Pressure Feedback Over-
flow Detection Time
Pressure Feedback Control
1 Pressure Feedback Loop
Differential Time
Pressure Feedback Control
1 Pressure Feedback Loop
Differential Filter Rate
Pressure Feedback Control
1 Pressure Feedback Loop
Proportional Gain 2
Sweep Torque Reference
Amplitude
Pressure Feedback Selec-
tion Switch 2
Gravity Compensation Ref-
erence Level for Torque
Control
Pressure Feedback Disable
Level
Reserved parameter
Reserved parameter
Reserved parameter
Continued on next page.
When
Enabled
*1
Immediately
Immediately
Immediately
Immediately
After restart
Immediately
Immediately
Immediately
Immediately
Immediately
Immediately
Immediately
Immediately
Immediately
Immediately
Immediately
Immediately
Immediately
After restart
Immediately
Immediately