YASKAWA SGD7S-R70A20A023F40B Product Manual page 94

Table of Contents

Advertisement

5.1 FT40 Specification
5.1.2 List of Alarms
Alarm
Number
A.d02
A.d0A
A.d10
A.d30
A.E02
A.E40
A.E41
A.E42
A.E50*
A.E51
A.E60*
A.E61
A.E63
A.E71
A.E72
A.E74
A.Eb1
A.EC8
A.EC9
A.Ed1
5-6
Alarm Name
Position Deviation Over-
flow Alarm for Speed Limit
at Servo ON
Pressure Feedback Loop
Deviation Overflow
Motor-Load Position Devi-
ation Overflow
Position Data Overflow
MECHATROLINK Internal
Synchronization Error 1
MECHATROLINK Trans-
mission Cycle Setting
Error
MECHATROLINK Commu-
nications Data Size Set-
ting Error
MECHATROLINK Station
Address Setting Error
MECHATROLINK Syn-
chronization Error
MECHATROLINK Syn-
chronization Failed
Reception Error in
MECHATROLINK Commu-
nications
Synchronization Interval
Error in MECHATROLINK
Transmission Cycle
MECHATROLINK Syn-
chronization Frame Not
Received
Safety Option Module
Detection Failure
Feedback Option Module
Detection Failure
Unsupported Safety
Option Module
Safety Function Signal
Input Timing Error
Gate Drive Error 1
Gate Drive Error 2
Command Execution Tim-
eout
Alarm Meaning
If position deviation remains in the deviation
counter, the setting of Pn529 or Pn584 (Speed
Limit Level at Servo ON) limits the speed when
the servo is turned ON. This alarm occurs if a
position reference is input and the setting of
Pn520 (Position Deviation Overflow Alarm Level)
is exceeded before the limit is cleared.
The difference between the pressure feedback
reference and the feedback detection value
exceeded Pn447 (Pressure Feedback Loop Devi-
ation Overflow Level).
There was too much position deviation between
the motor and load during fully-closed loop con-
trol.
The position feedback data exceeded
±1,879,048,192.
A synchronization error occurred during MECHA-
TROLINK communications with the SERVO-
PACK.
The setting of the MECHATROLINK communica-
tions transmission cycle is not correct.
The setting of the MECHATROLINK communica-
tions data size is not correct.
The setting of the MECHATROLINK station
address is not correct.
A synchronization error occurred during MECHA-
TROLINK communications.
Synchronization failed during MECHATROLINK
communications.
Communications errors occurred continuously
during MECHATROLINK communications.
An error occurred in the transmission cycle
during MECHATROLINK communications.
Synchronization frames were continuously not
received during MECHATROLINK communica-
tions.
Detection of the Safety Option Module failed.
Detection of the Feedback Option Module failed.
An unsupported Safety Option Module was con-
nected.
An error occurred in the input timing of the safety
function signal.
An error occurred in the gate drive circuit.
An error occurred in the gate drive circuit.
A timeout error occurred for a MECHATROLINK
command.
Continued from previous page.
Servo-
Alarm
motor
Reset
Stop-
Possi-
ping
ble?
Method
Gr.2
Yes
Gr.1
Yes
Gr.2
Yes
Gr.1
No
Gr.1
Yes
Gr.2
Yes
Gr.2
Yes
Gr.2
No
Gr.2
Yes
Gr.2
Yes
Gr.2
Yes
Gr.2
Yes
Gr.2
Yes
Gr.1
No
Gr.1
No
Gr.1
No
Gr.1
No
Gr.1
No
Gr.1
No
Gr.2
Yes
Continued on next page.

Advertisement

Table of Contents
loading

Table of Contents