Warning Number:
Possible Cause
Warning Name
The power supply
voltage exceeded
the specified
range.
There is insuffi-
cient external
regenerative resis-
tance, regenera-
A.920:
tive resistor
Regenerative Over-
capacity, or SER-
load (warning before
VOPACK capac-
an A.320 alarm
ity, or there has
occurs)
been a continuous
regeneration
state.
There was a con-
tinuous regenera-
tion state because
a negative load
was continuously
applied.
The Servomotor
was rotated by an
external force.
When the Servo-
motor was
A.921:
stopped with the
dynamic brake,
Dynamic Brake
the rotational or
Overload (warning
before an A.731
linear kinetic
alarm occurs)
energy exceeded
the capacity of the
dynamic brake
resistor.
A failure occurred
in the SERVO-
PACK.
The pressure
feedback detec-
tion value
exceeded the
level set in Pn44D
A.922:
(Pressure Feed-
Pressure Feedback
back Overflow
Overflow
Detection Level)
for the time set in
Pn44E (Pressure
Feedback Over-
flow Detection
Time).
A.923:
The fan inside the
SERVOPACK
SERVOPACK Built-
in Fan Stopped
stopped.
Confirmation
Set the power supply volt-
Measure the power
age within the specified
supply voltage.
range.
Change the regenerative
resistance value, regenera-
Check the operating
tive resistance capacity, or
conditions or the
SERVOPACK capacity.
capacity using the Sig-
Reconsider the operating
maJunmaSize+ Capac-
conditions using the Sigma-
ity Selection Software
JunmaSize+ Capacity
or another means.
Selection Software or other
means.
Reconsider the system
Check the load applied
including the servo,
to the Servomotor
machine, and operating
during operation.
conditions.
Implement measures to
Check the operation
ensure that the motor will
status.
not be rotated by an exter-
nal force.
Reconsider the following:
• Reduce the Servomotor
Check the power con-
command speed.
sumed by the DB resis-
• Decrease the moment of
tor to see how
inertia or mass.
frequently the DB is
• Reduce the frequency of
being used.
stopping with the dynamic
brake.
The SERVOPACK may be
faulty. Replace the SERVO-
PACK.
Check the output from
Adjust the pressure sensor
the pressure sensor
amplifier.
amplifier.
Check the setting of
Change the setting of
Pn449 (Pressure Feed-
Pn449 (Pressure Feedback
back Sensor Gain).
Sensor Gain).
Remove foreign matter from
Check for foreign mat-
the SERVOPACK. If an
ter inside the SERVO-
alarm still occurs, the SER-
PACK.
VOPACK may be faulty.
Replace the SERVOPACK.
5.1 FT40 Specification