High-Voltage Transformer (Ac) - Canon imageRUNNER 5065 series Service Manual

Table of Contents

Advertisement

[3]
[3]
[1]

10.5.17 High-Voltage Transformer (AC)

10.5.17.1 Before Removing High Voltage Transformer
iR5065 / iR 5055 / iR5075 / / /
1) Remove the charger unit (this step is necessary only for iR5075 for Japan).
(page 10-20)Reference[Removing the Charger unit]
2) Remove the rear cover (upper). (page 10-11)Reference[Removing the
Rear Cover (Upper)]
3) Detach the rear cover (lower). (page 10-11)Reference[Removing the
Rear Cover (Lower)]
10.5.17.2 Removing High Voltage Transformer
iR5075 /
1) Remove the transformer unit [3] by sliding it to the left.
- 2 screws [1]
- 3 connectors [2]
[3]
[2]
2) Remove the transformer [4].
- 2 screws [1]
- 1 wire saddle [2]
- 1 connector [3]
[4]
[2]
F-10-85
[2]
[1]
F-10-86
10.5.17.3 Removing High Voltage Transformer
iR5065 / iR 5055 / /
1) Remove the transformer unit [3] by sliding it to the left.
- 2 screws [1]
- 2 connectors [2]
0015-9479
0015-9478
[3]
2) Remove one connector [1] on the HVT PCB.
3) Remove the transformer [2].
- 2 screws [1]
[3]
[2]
[1]
[4]
[1]
F-10-87
[2]
[1]
F-10-88
[1]
F-10-89
Chapter 10
0016-1513
10-25