Uploading And Downloading Backup Data - Canon imageRUNNER 5065 series Service Manual

Table of Contents

Advertisement

3) When the downloading session has ended, click [OK].
4) When you are done, turn off and then on the main power of the machine.
5) See the status of upgrading indicated on the control panel of the machine. When a message appears asking you to turn off and then on the machine, turn off and
then on the main power.
You will not be able to download G3Fax twice in succession. (Once downloading is executed, the board will be reset, causing download mode to end.)
Be sure never to turn off the machine while it is executing a downloading session or writing downloaded system software. Otherwise, the write operation (to the
flash ROM DIMM of the G3 fax board) may fail, preventing board functions. In the event the board fails to function, be sure to replace the flash ROM DIMM found
on the G3 fax board.

18.4.10 Uploading and Downloading Backup Data

18.4.10.1 Outline
iR5065 / iR 5055 / iR5075 / / /
SramImg is data that is stored in the SRAM of the main controller PCB, while MeapBack is a MEAP application and its data stored on the HDD.
Backup data
Main controller PCB backup RAM
MEAP application
for R&D
F-18-51
F-18-52
T-18-5
Files to select for downloading/uploading
SramImg.bin
MeapBack.bin
Sublog.txt