(deg c)
[1] Fixing roller 1/4-speed rotation
[2] Fixing roller 1/1-speed rotation

9.2.4 High-Humidity Environment Start-Up Mode

iR5065 / iR 5055 / iR5075 / / /
<Conditions of Use>
When all the following conditions exist:
- the site is a high-humidity environment (absolute moisture content is 13 g or more)
- the temperature of the fixing roller is 70 deg C or lower
<Characteristics>
- The target temperature for the fixing roller is 205 deg C.
- If all the following condition exist, the machine shifts to standby mode:
the temperature of the fixing roller has reached the target temperature.
drum potential control has ended.
60 sec (*1) has passed from power-on.
(deg c)
[1] Fixing roller 1/4-speed rotation
[2] Fixing roller 1/1-speed rotation

9.2.5 Recovery Mode

iR5065 / iR 5055 / iR5075 / / /
<Conditions of Use>
- The temperature of the fixing roller is 70 deg C or higher.
<Characteristics>
- The target temperature of the fixing roller varies according to the environment temperature.
185 deg C if the environment temperature is 17 deg C or higher
195 deg C if the environment temperature is lower than 17 deg C
- When the temperature of the fixing roller reaches the target temperature, the machine shifts to standby mode.
- It takes 30 sec less for the machine to shift from power-on to standby states.
POWER ON
250
200
180
150
100
50
0
0
5
10
15
20
25
POWER ON
250
200
180
150
[1]
100
50
0
0
5
10
15
20
[1]
30
35
40
45
50
55
60
F-9-7
[2]
25
30
35
40
45
50
F-9-8
STANDBY
[2]
65
70
75
80
(sec)
STANDBY
55
60
65
70
(sec)
Chapter 9
0015-4588
0015-4590
9-5