Reversing Unit; Before Removing The Reversing Sensor 2 - Canon imageRUNNER 5065 series Service Manual

Table of Contents

Advertisement

Chapter 8
8.10.32.2 Removing the Reversing Sensor 1
iR5065 / iR 5055 / iR5075 / / /
1) Remove the Sensor together with the mount [3].
- 2 screws [1]
- 1 grounding wire [2]
[1]
2) Remove the sensor [2].
- 1 connector [1]
[1]

8.10.32.3 Before Removing the Reversing Sensor 2

iR5065 / iR 5055 / iR5075 / / /
1)
Detach
the
duplexing
12)Reference[Removing the Duplexing Feed Front Cover]
2) Remove the duplex feeding unit.(page 8-44)Reference[Removing the
Duplex Feeding Unit]
8.10.32.4 Removing the Reversing Sensor 2
iR5065 / iR 5055 / iR5075 / / /
1) Remove the sensor together with the mount [3].
- 2 screws [1]
- 1 grounding wire [2]
[1]
[3]
2) Remove the sensor [2].
- 1 connector [1]
8-42
[2]
[3]
[1]
F-8-138
[2]
F-8-139
feed
front
cover.(page
[2]
[1]
F-8-140
0015-9397

8.10.33 Reversing Unit

8.10.33.1 Before Removing the Reversing Flapper
Solenoid
iR5065 / iR 5055 / iR5075 / / /
1)
Detach
the
12)Reference[Removing the Duplexing Feed Front Cover]
2) Remove the duplex feeding unit.(page 8-44)Reference[Removing the
Duplex Feeding Unit]
8.10.33.2 Removing the Reversing Flapper Solenoid
iR5065 / iR 5055 / iR5075 / / /
1) Free the harness [3] from the guide [2].
- 1 connector [1]
2) Remove the reversing flapper solenoid [6].
- 2 screws [4]
- 1 grounding wire [5]
0015-9404
10-
[2]
0015-9398
8.10.33.3 Mounting the Reversing Flapper Solenoid
iR5065 / iR 5055 / iR5075 / / /
Before removing the screw, make sure to mark the line in the following step.
1) Adjust the position of the solenoid using the 2 screws [1] so that the driver
lever [2] is pushed fully when the solenoid is on (i.e., when the plunger is
down)
[1]
[2]
F-8-141
duplexing
feed
front
cover.(page
[4]
[1]
[5]
[3]
[4]
[6]
F-8-142
0015-9405
10-
0015-9391
0016-0028

Advertisement

Table of Contents
loading