Chapter 9
- Applied grease may be transferred from the bushing to the fixing roller
ends [1] when mounting; be sure to wipe it off when this happens.

9.5.4.5 Adjusting the Nip Width

iR5065 / iR 5055 / iR5075 / / /
The nip width adjustment is not necessary.

9.5.5 External Delivery Roller

9.5.5.1 Before Removing the External Delivery Roller

iR5065 / iR 5055 / iR5075 / / /
1)
Detach
the
duplexing
12)Reference[Removing the Duplexing Feed Front Cover]
2) Detach the fixing/feeding unit. (page 9-18)Reference[Removing the
Fixing/Feeding unit]

9.5.5.2 Removing the External Delivery Roller

iR5065 / iR 5055 / iR5075 / / /
1) Remove the delivery roller guide [2].
- 2 screws [1]
2) Remove the bushing [2] and the delivery unit [3].
- 1 screw [1]
9-24
[2]
[1]
F-9-55
[1]
F-9-56
feed
front
cover.
(page
[2]
[1]
F-9-57
When putting the removed delivery unit aside temporarily, place the unit to
the orientation as shown in the figure below. The separation claw may be
damaged if the claw hit against the floor.
0015-9977
0015-7190
10-
3) Remove the external delivery roller [9].
- 1 E-ring [1]
- 1 O-ring [4]
- 1 bushing [3]
(at the front)
- 1 E-ring [4]
- 1 gear [5]
0015-5052
- 1 E-ring [6]
- 1 O-ring [7]
- 1 bushing [8]
(at the rear)
[1]
[3]
[2]
F-9-58
F-9-59