Table of Contents

Advertisement

Chapter 10
Copier/printer operation
Finisher mode
The counters may be grouped into 8 types, a total of 16 individual types when further divided according to paper size (large and small); specifically,
Copier/printer mode
Local copy
PDL print
Box print
Remote copy print
Fax reception print
Report print
Duplex print
Scan
*1: at time of shipmen, B4 or smaller.
If the user wants B4 to be counted as a large size, the setting may be changed in service mode.
The following shows the default counter types valid at time of shipment:
100V
120 V, 230 V (outside Europe)
230V (inside Europe)
*1: the notation in parentheses indicates the support mode of the basic counter.
*2: the counter type may be changed or counter display may be enabled or disabled in service mode (not applicable to counter 1).

10.3 Fans

10.3.1 Arrangement, Functions, and Error Codes
iR5065 / iR 5055 / iR5075 / / /
The following shows the names of the fans mounted to the machine and the functions and error codes associated with
them:
Notation
Name
FM1
feed fan
FM2
primary charging cooling fan
FM3
heat discharge fan
FM4
controller cooling fan
FM5
curl-removing fan
FM6
DC power supply fan
10-2
Counter
Description*1
counter 1
total (A through L)
counter 2
-
counter 3
-
counte 4
-
counter 5
-
counter 6
-
Counter
Description*1
counter 1
total (A through L)
counter 2
total, large (ACEGIK)
counter 3
copy (total 1; ABGH)
counter 4
copy (large; AG)
counter 5
-
counter 6
-
Counter
Description*1
counter 1
total (A through L)
counter 2
total, large (ACEGIK)
counter 3
total, small (BDFHJL)
counter 4
scan (total 1; OP)
counter 5
-
counter 6
-
Function
keeps print paper to feed belt
cools the primary charging assembly and the cleaner
discharges exhaust of fans outside the machine
cools the laser unit, developing block drive block, and
controller
removes curl from print paper after fixing
cools power supply PCB
Counter name
delivery sensor
T-10-2
Large size
A
C
E
G
I
K
M
O
T-10-3
Default
Change
ON
not possible
OFF
possible
OFF
possible
OFF
possible
OFF
possible
OFF
possible
T-10-4
Default
Change
ON
not possible
ON
possible
ON
possible
ON
possible
OFF
possible
OFF
possible
T-10-5
Default
Change
ON
not possible
ON
possible
ON
possible
ON
possible
OFF
possible
OFF
possible
T-10-6
T-10-7
2-speed control (voltage) Error code
yes (24/12 V)
yes (24/12 V)
yes (24/12 V)
yes (24/12 V)
yes (24/12 V)
yes (24/12 V)
Small size*1
B
D
F
H
J
L
N
P
E805-0002
E824-0001
E805-0001
E121-0001
-
E804-0000
0015-4629

Advertisement