Main Drive Assembly; Fitting The Drive Belt; Cassette Pickup Drive Assembly; Before Removing The Cassette Pickup Drive Assembly - Canon imageRUNNER 5065 series Service Manual

Table of Contents

Advertisement

[1]
6) Remove the collecting toner drive assembly [2].
- 3 screws [1]
[2]

10.5.6 Main Drive Assembly

10.5.6.1 Fitting the Drive Belt

iR5065 / iR 5055 / iR5075 / / /
Be sure that the drive belt is fitted to the pulley and the roller as shown in the
following figure.
[1] Main drive belt
[2] Pickup drive belt

10.5.7 Cassette Pickup Drive Assembly

10.5.7.1 Before Removing the Cassette Pickup Drive
Assembly
iR5065 / iR 5055 / iR5075 / / /
1) Remove the charger unit (this step is necessary only for iR5075 for Japan).
(page 10-20)Reference[Removing the Charger unit]
2) Remove the rear cover (upper). (page 10-11)Reference[Removing the
Rear Cover (Upper)]
3) Detach the rear cover (lower). (page 10-11)Reference[Removing the
Rear Cover (Lower)]
4) Detach the main controller box cover. (page 10-15)Reference[Remov-
ing the Main Controller Box Cover]
5) Removing the Right Cover (Upper Rear). (page 10-10)Reference[Re-
moving the Right Cover (Upper Rear)]
6) Remove the main controller box. (page 4-13)Reference[Removing the
[2]
F-10-55
[1]
[1]
F-10-56
F-10-57
Main Controller Box]
7) Detach the right cover (lower rear). (page 10-10)Reference[Removing
the Right Cover (Lower Rear)]
8)
Remove
the
28)Reference[Removing the Collecting Toner Bottle Holder]

10.5.7.2 Removing the Cassette Pickup Drive Assembly

iR5065 / iR 5055 / iR5075 / / /
1) Disconnect the 10 connectors on the motor driver PCB.
2) Remove the motor driver PCB mounting base [3].
- 9 wire saddles (Free the harness [1])
- 4 screws [2]
[2]
[2]
0015-5103
- The removal procedure of the right deck pickup assembly and the cassette
3/4 pickup assembly is the same.
- An illustration uses a right door pickup assembly as an example to explain.
- An attempt removing the pickup assembly without removing the deck/
cassette causes the lifter get trapped and may hold the pickup assembly
from sliding out.
3) Slide out the cassette 3 and the cassette 4.
4) Open the manual tray cover and the right cover (lower).
5) Disconnect the connector [3].
- 1 screw [1]
- 1 connector cover [2]
6) Remove the pickup assembly [5].
- 3 screws [4]
[4]
0015-6548
7) Remove the cassette pickup drive assembly [2].
- 3 screws [1]
collecting
toner
bottle
holder.
[3]
[1]
[2]
[1]
F-10-58
[4]
[2]
[3]
[1]
[5]
F-10-59
Chapter 10
(page
5-
0015-5111
[1]
[2]
10-19

Advertisement

Table of Contents
loading