Basic Sequence Of Operation (At Power-On; High-Humidity Start-Up Mode) - Canon imageRUNNER 5065 series Service Manual

Table of Contents

Advertisement

Chapter 3
Main motor
(M2)
Drum motor
(M1)
Pre-exposure
LED (LED1)
Primary charging
Laser
Developing clutch
(CL1)
Developing bias
(DC)
Developing bias
(AC)
Bias roller
Pre-transfer
charging (DC)
Pre-transfer
charging (AC)
Transfer charging
Separation
charging (DC)
Separation
charging (AC)
Fixing motor
(M3)
Fixing heater
(IH)
*1: After a shift to standby, the fixing target temperature is decreased in 5-deg C increments at specific time intervals. When a specific temperature is reached, the
fixing heater and the fixing motor are turned on and off to maintain the temperature.
Interval
WMUPR (warm-up)
CNTR (control rotation)
PSTBY (print standby)

3.2.3 Basic Sequence of Operation (at power-on; high-humidity start-up mode)

iR5065 / iR 5055 / iR5075 / / /
Main motor
(M2)
Drum motor
(M1)
Pre-exposure
LED (LED1)
Primary charging
Laser
Developing clutch
(CL1)
Developing bias
(DC)
Developing bias
(AC)
Bias roller
Pre-transfer
charging (DC)
Pre-transfer
charging (AC)
Transfer charging
Separation
charging (DC)
Separation
charging (AC)
Fixing motor
(M3)
Fixing heater
(IH)
*1: After a shift to standby, the fixing target temperature is decreased in 5-deg C increments at specific time intervals. When a specific temperature is reached, the
3-4
Main power
switch ON
WMUPR
60 sec (approx.)
Description
From when the main power is turned on until the fixing roller temperature reaches a
specific level and, in addition, the potential control of the photosensitive drum ends, and as much as 60 sec passes from
power-on.
The machine executes potential control of the photosensitive drum. For each mode (i.e., copier, printer), the machine
executes VD control (to adjust the primary discharge current) and Vl control (to adjust the laser output), and determines Vdc
(developing bias).
The machine is in a state in which it is ready to accept a copy/print request signal.
Main power
switch ON
WMUPR
60 sec (approx.)
CNTR
215 deg C
F-3-5
T-3-3
CNTR
205 deg C
F-3-6
PSTBY
*1
PSTBY
*1
0015-4349