Omron NX-SL3300 User Manual page 70

Nx series safety control unit
Hide thumbs Also See for NX-SL3300:
Table of Contents

Advertisement

2 Specifications
Item
External connection termi-
nals
Indicators
Hardware switch settings
Dimensions (mm)
I/O power supply method
Current capacity of I/O power
supply terminal
NX Unit power consumption
Current consumption from
I/O power supply
Weight
Installation orientation and
restrictions
*1.
Refer to 5-4-3 Calculating the Number of Connections on page 5 - 20 for how to calculate the number of
connections.
*2.
The number of CIP Safety connections that can be actually set depends on the maximum number of routa-
ble CIP Safety connections of the NX-series CPU Unit.
For NX102 CPU Units, the maximum number of routable CIP Safety connections is 16.
l NX-SL3300
Maximum number of safety I/O points
Program capacity
Number of safety I/O connections
Number of CIP Safety originator connections
Number of CIP Safety target connections
Number of originators that can be connected
with a multi-cast connection
Number of FSoE master connections
I/O refreshing method
External connection terminals
Indicators
Hardware switch settings
Dimensions (mm)
I/O power supply method
Current capacity of I/O power supply terminals No I/O power supply terminals
2 - 4
The type of terminal block and connector that is used for connecting the Unit.
This specification includes the number of terminals for a screwless clamping
terminal block.
The type of indicators on the Unit and the layout of those indicators.
It is the type and layout of hardware switches for the Unit.
These are the external dimensions of the Unit. The dimensions are given in
the form W × H × D. The dimensions are given in "millimeters".
The method for supplying I/O power for the Unit. The supply method is deter-
mined for each Unit. The power can be supplied either from the NX bus or
from an external source.
The current capacity of the I/O power supply terminals (IOV/IOG) of the Unit.
Do not exceed this value when supplying the I/O power to the connected ex-
ternal devices.
The power consumption of the NX Unit power supply of the Unit.
The current consumption from I/O power supply of the Unit. This value does
not include the load current of any external connection loads or the current
consumption of any connected external devices.
The weight of the Unit.
This is the installation orientation of the Unit. Any restrictions to specifications
that result from the installation orientation are also given.
Item
Description
Specification
256 points
512 KB
32
0
0
0
32
Free-Run refreshing
None
[FS] LED, [VALID] LED, [DEBUG] LED, [TS] LED, [RUN]
LED
None
30 × 100 × 71 mm (W × H × D)
Not supplied.
NX-series Safety Control Unit User's Manual (Z930)

Advertisement

Table of Contents
loading

Table of Contents