Omron NX-SL3300 User Manual page 371

Nx series safety control unit
Hide thumbs Also See for NX-SL3300:
Table of Contents

Advertisement

Information
Communications Status
Error Status
Operating Mode
Synchronization Status
Variable in Forced Refreshing
Safety Data Communications
Program Execution
Synchronise Details
Additional Information
You can use the color of the top of the Edit Pane to check if you are online with the Safety CPU
Unit or connected to the Safety Simulator.
• Connected to the Safety CPU Unit online
The top of the Edit Pane is yellow.
• Connected to the Safety Simulator:
The top of the Edit Pane is green.
NX-series Safety Control Unit User's Manual (Z930)
7 Checking Operation and Actual Operation
Displayed information and indicator colors
Displays the communications status between the Safety CPU Unit and Sys-
mac Studio or displays the Simulator startup status.
Normal communications: Lit green
Communications error: Flashing red
Displays the error status of the Safety CPU Unit or Simulator.
No Controller error: Lit green
Partial or minor fault level Controller error occurs: Lit yellow.
Displays the operating mode of the Safety CPU Unit.
RUN Mode: Lit yellow.
DEBUG mode (RUN): Flashing yellow.
DEBUG mode (STOPPED): Flashing yellow.
PROGRAM Mode: Not lit.
UNKNOWN Mode: Flashing red.
Displays the comparison results between the project file on the computer
and the data in the Safety CPU Unit.
Synchronized: Lit green.
Not synchronized/not executed: Lit yellow.
Displays the forced-refreshing status of variables in the safety programs.
None
Present
It shows the status of communications among the Safety CPU Unit, the
FSoE slave device, and the CIP Safety target device.
No error or no communications
Communications error
Displays the execution status of the safety programs.
Executing - no errors
Executing - instruction error
Not executing
Displays the synchronization information item, last modified date, and sig-
nature (CRC data).
7
7 - 65