The following table shows values set to input variables of the function block.
Input variable name
Activate
S_StartReset
S_AutoReset
Reset
MonitoringTime
Any other input variables Variable automatically generated based on the following naming rule:
2
EMO_NC_S1
Reset_S2_Out
3
l Generation of Logical Operation Circuit
At this step, an AND logic function is generated for each output variable based on the Expected
Value Settings in the Automatic Programming Settings Tab Page.
The internal variables, which are automatically generated at the input signal generation, are used
as input variables for the AND function. In addition, the output variable of the AND function is auto-
matically generated as an internal variable and is used as an input signal at the following output
signal generation.
NX-series Safety Control Unit User's Manual (Z930)
TRUE
FALSE
Value specified for the reset type
Manual: FALSE
Auto: TRUE
Variable generated in the reset signal generation step
t#300ms
FB Instance Name_Input Variable Name
Emergency Stop Pushbutton S1
SF_EmergencyStop_0
SF_EmergencyStop
TRUE
Activate
S_EStopIn
FALSE
S_StartReset
FALSE
S-AutoReset
Reset
Safety Laser Scanner S3
TRUE
Activate
LaserScanner_S3
S_ESPE_In
FALSE
S_StartReset
TRUE
S-AutoReset
Reset_S2_Out
Reset
Setting value
Ready
S_EStopOut
Error
DiagCode
SF_ESPE_0
SF_ESPE
Ready
S_ESPE_Out
Error
DiagCode
6 Programming
EMO_NC_S1_Out
LaserScanner_S3_Out
6 - 69
6