12 Troubleshooting
Event code
Event name
80300000 hex
Safety Proc-
ess Data
[NX-SL3£££]
Communica-
tions Time-
out
80300001 hex
FSoE Mas-
ter Connec-
[NX-SL5£££]
tion Timeout
80310000 hex
CIP Safety
Originator
[NX-SL5£££]
Connection
Not Estab-
lished Error
80320000 hex
CIP Safety
Originator
[NX-SL5£££]
Connection
Timeout
80330000 hex
CIP Safety
Target Does
[NX-SL5£££]
Not Exist
12 - 20
Meaning
•
A communications
A setting is not correct. The
timeout occurred in
setting of the safety task peri-
safety process data
od is too short.
•
communications with
There is excessive noise.
the Safety Control
•
The Safety CPU Unit or safety
Unit.
slave entered a status where it
could not continue safety proc-
ess data communications.
•
The process data communica-
tions were not performed cor-
rectly because an error or sta-
tus change occurred in the NX
bus master to which the Unit is
connected.
•
A communication
A setting is not correct. The
timeout occurred in
setting of the safety task peri-
FSoE communica-
od is too short.
•
tions with the FSoE
There is excessive noise.
•
slave.
The Safety CPU Unit or FSoE
slave entered a state where it
could not continue FSoE com-
munications.
•
The process data communica-
tions were not performed cor-
rectly because an error or sta-
tus change occurred in the NX
bus master to which the Unit is
connected.
•
CIP safety originator
The target node is different.
•
connection was not
The target node is not config-
established.
ured.
•
The target node status is inva-
lid.
•
A timeout occurred in
The communications cable is
CIP safety originator
disconnected or broken.
•
connection.
The target node entered a
state where it could not accept
the connection.
•
The timeout value in the com-
munications setup is too small.
•
There is excessive noise.
•
The target node does
The communications cable is
not exist.
disconnected or broken.
•
The target node entered a
state where it could not accept
the connection.
•
The timeout value in the com-
munications setup is too small.
•
There is excessive noise.
M
Assumed cause
a
j