Omron NX-SL3300 User Manual page 596

Nx series safety control unit
Hide thumbs Also See for NX-SL3300:
Table of Contents

Advertisement

Appendices
General
Status
(hex)
01
011D
01
011E
01
011F
01
0120
01
0121
01
0122
01
0123
01
0124
01
0125
01
0126
01
0127
01
0128
01
0129
01
012A
01
012B
01
012C
01
012D
01
012E
01
012F
01
0130
01
0131
01
0132
01
0133
01
0134
01
0135
01
0136
01
0137
01
0138
01
0139
01
0203
01
0204
01
0205
01
0206
01
0207
01
0301
01
0302
01
0303
01
0304
01
0305
01
0306
01
0311
01
0312
01
0315
01
0316
A - 84
Additional
Status
(hex)
T->O Production Trigger not supported
Direction not supported
Invalid originator to target Network Connection Fixvar
Invalid target to originator Network Connection Fixvar
Invalid originator to target Network Connection Priority
Invalid target to originator Network Connection Priority
Invalid originator to target Network Connection Type
Invalid target to originator Network Connection Type
Invalid originator to target Network Connection Redundant_Owner
Invalid configuration size
Invalid originator to target Network Connection Size
Invalid target to originator Network Connection Size
Invalid Configuration Application Path
Invalid Consuming Application Path
Invalid Producing Application Path
Configuration Symbol does not exist
Consuming Symbol does not exist
Producing Symbol does not exist
Inconsistent Application Path combination
Inconsistent Consume Data Format
Inconsistent Produce Data Format
Null Forward Open function not supported
Connection Timeout Multiplier not acceptable
Mismatched T->O Network Connection Size
Mismatched T->O Network Connection Fixvar
Mismatched T->O Network Connection Priority
Mismatched Transport Class
Mismatched T->O Production Trigger
Mismatched T->O Production Inhibit Time Segment
Connection cannot be closed because the connection has timed out.
Unconnected_Send service timed out while waiting for a response.
Parameter Error in Unconnected Send Service or Parameter Error in SafetyOpen
or SafetyClose
Message too large for unconnected message service.
Unconnected acknowledgement without reply.
No buffer memory available.
Network bandwidth not available for data.
No tag filters available.
Not configured to send real-time data.
Schedule Signature mismatch
Schedule Signature validation not possible
Port that was specified in port segment is not available.
Link address that was specified in port segment is not available.
Invalid segment type or segment value in path.
Path and connection were not equal when closing the connection.
Explanation
NX-series Safety Control Unit User's Manual (Z930)

Advertisement

Table of Contents
loading

Table of Contents