6 Programming
Deleting Jump Instructions
Use one of the following procedures to delete a Jump instruction.
Method
Method 1 Right-click the Jump Instruction select Delete from the menu.
Method 2 Select the Jump Instruction and press the Delete Key.
The selected Jump instruction is deleted.
Inserting Return Instructions
Use one of the following procedures to insert a Return instruction in a network.
Method
Method 1 Drag Return from General in the Toolbox to a terminal in the FBD editor, or to a new FBD network
where the words Start here are displayed.
Method 2 Right-click the FBD network and select Insert Return from the menu.
The Return instruction is inserted in the network.
• After you insert a return instruction, the network is laid out as shown below.
Deleting Return Instructions
Use one of the following procedures to delete a Return instruction.
Method
Method 1 Right-click the Return instruction and select Delete from the menu.
Method 2 Select the Return instruction and press the Delete Key.