Application Overview
Safety category/PL
Equivalent to 3/PLd
(Safety Mat)
Safety light curtain monitors apertural area of safeguarded space and safety mat monitors inside of
safeguarded space.
If the light in safety light curtain S3 is interrupted or safety mat S4 detects a person or object, motor M
will stop.
Wiring
NX-series Safety Control Unit User's Manual (Z930)
Safety device
Emergency stop pushbutton
Safety light curtain
Safety mat
Appendices
Stop category
Reset