Step
Step 5-4 Connecting the
Computer That Runs the
Sysmac Studio
*1.
You can use this connection method only if you use an NJ/NX-series CPU Unit and EtherCAT Coupler Unit.
Step 6. Checking Operation
Step
Step 6-1 Changing to DE-
BUG Mode After Transfer-
ring the Slave Terminal
Configuration Information
Step 6-2 Checking Opera-
tion Using the Controller
Step 6-3 Performing Safety
Validation Testing
Step 6-4 Designing Device
Security
Step 6-5 Validating Safety
from the Sysmac Studio
*1.
You can use this connection method only if you use an NJ/NX-series CPU Unit and EtherCAT Coupler Unit.
Step 7. Operation, Maintenance, and Inspection
Step
Step 7-1 Operation
NX-series Safety Control Unit User's Manual (Z930)
Description
Use one of the following connections.
Connect a USB cable to the NJ/NX-series
*1
CPU Unit
Connect an Ethernet cable to the built-in
EtherNet/IP port on the NJ/NX-series CPU
Unit.*1
Connect a USB cable to the Communications
Coupler Unit
Description
Place the Sysmac Studio online with the NJ/NX-
*1
series CPU Unit
or the Communications Cou-
pler Unit and then transfer the Slave Terminal
configuration information.
Then, change the Safety CPU Unit from the
Safety CPU Unit Setup and Programming View.
This transfers the safety application data to the
Safety CPU Unit and enables debugging.
Check all wiring and the operation of the pro-
gram to check that the Safety Control Unit oper-
ates as intended.
Test all safety functions to see if they operate
according to designs.
Set the safety passwords.
After the safety validation testing has been
passed, execute the Safety Validation operation
from the Sysmac Studio.
This transfers the safety application data to the
non-volatile memory in the Safety CPU Unit and
enables operation.
Description
Restart the Safety CPU Unit.
If the Safety CPU Unit has a validated user pro-
gram, the Safety CPU Unit will automatically
start in RUN mode.
1 Overview
Reference
1-3 Support Software on page
1 - 12
Refer to the Sysmac Studio
Version 1 Operation Manual
(Cat. No. W504)
Manuals for specific Communi-
cations Coupler Units
Reference
7-2 Transferring the Configura-
tion Information on page
7 - 7
7-3 Operating Modes of the
Safety CPU Unit on page
7 - 11
7-4 Changing to DEBUG Mode
on page 7 - 17
7-6 Functions for Checking Op-
eration on page 7 - 27
7-6 Functions for Checking Op-
eration on page 7 - 27
7-9 Security Settings on page
7 - 51
7-10 Performing Safety Valida-
tion and Operation on page
7 - 56
Reference
7-10 Performing Safety Valida-
tion and Operation on page
7 - 56
1 - 19