4 Safety Control Unit Operation
Refer to Precaution for Conformance to ISO 13856-1:2013 on page 8 - 4 for precautions on con-
formance to ISO 13856-1:2013.
Precautions for Correct Use
• The maximum number of connections per Unit is as follows:
NX-SIH400: 12 (12 connected in series × 1 series)
• You can connect up to 12 Safety Mats to the two test output terminals.
• You cannot branch the connections to more than one Safety Mat or Safety Edge from the
same test output terminal.
NX-SIH400
• The total wiring length (L1 + L2 +...+ Ln+1) for the UM/UMA Safety Mats is 100 m max.
• The UM/UMA Safety Mats can be used in a Safety Category 3 or lower or a PLd or lower
application. They cannot be used in a Safety Category 4 or PLe application.
l SGE Safety Edges
OMRON SGE Safety Edges are connected as shown in the following figure.
4 - 20
T0
T1
Black
Blue
Si0
Brown
White
Si1
Black
Blue
Si2
Brown
White
Si3
Safety mat