Mitsubishi Electric MELSEC iQ-F FX5 User Manual page 223

Analog control - intelligent function module
Hide thumbs Also See for MELSEC iQ-F FX5:
Table of Contents

Advertisement

• For CLEAR
If the CPU changes from RUN to STOP, the wave output terminates and the offset value is output. When 'CH1 Output enable/
disable flag' (Un\G70, b1) is turned on with the CPU module changed from STOP to RUN, the output changes as per the
setting of 'CH1 Output setting during wave output stop' (Un\G524). Wave output does not restart.
To perform the wave output, change the CPU module from STOP to RUN and then set 'CH1 Wave output start/stop request'
(Un\G462) to Wave output stop request (0). Then, change 'CH1 Wave output start/stop request' (Un\G462) from Wave output
stop request (0) to Wave output start request (1).
CPU module status
CH1 D/A conversion
enable/disable setting (Un\G500)
CH1 Output enable/disable flag
(Un\G70, b1)
CH1 Wave output start/stop
request (Un\G462)
CH1 Wave output status monitor
(Un\G401)
Wave data
Output value as per the setting of CH1 Output
setting during wave output stop (Un\G524)
The output is disabled because the CPU module changes from RUN to STOP.
Once the HOLD/CLEAR operates, the wave output stops.
Outputs the offset value.
To restart the wave output, change the setting to Wave output start request (1).
RUN
OFF
ON
Wave output stop request (0)
Wave output stopped (0)
Analog output
Offset value
STOP
D/A conversion enable (0)
OFF
Wave output start request (1)
Wave output
Wave output stopped (0)
in progress (1)
CLEAR
RUN
ON
Wave output
Wave output
stop request (0)
start request (1)
Wave output
in progress (1)
2 FX5-4DA
2.4 Functions
2
221