Appendix 6 Standards; Certification Of Ul, Cul Standards; Compliance With Ec Directive (Ce Marking); Requirement For Compliance With Emc Directive - Mitsubishi Electric MELSEC iQ-F FX5 User Manual

Analog control - intelligent function module
Hide thumbs Also See for MELSEC iQ-F FX5:
Table of Contents

Advertisement

Appendix 6

Certification of UL, cUL standards

The FX5-4DA supports UL (UL, cUL) standards.
For models that support UL standards, refer to the following.
UL, cUL file number: E95239

Compliance with EC directive (CE marking)

This note does not guarantee that an entire machine produced in accordance with the contents of this note will comply with
the following standards.
Compliance to EMC directive and LVD directive of the entire mechanical module should be checked by the user/
manufacturer. For more details please contact to the local Mitsubishi Electric sales site.

Requirement for compliance with EMC directive

The following products have shown compliance through direct testing (of the identified standards below) and design analysis
(through the creation of a technical construction file) to the European Directive for Electromagnetic Compatibility (2014/30/
EU) when used as directed by the appropriate documentation.
Attention
This product is designed for use in industrial applications.
Product compatibility
Type: Programmable controller (open type equipment)
Models: FX5 manufactured
from November 1st, 2017
Electromagnetic compatibility (EMC) directive
EN61131-2:2007 Programmable controllers
- Equipment requirements and tests

Caution for compliance with EC directive

Caution for when the FX5-4DA is used
When the FX5-4DA is used, attach a ferrite core to the power supply of the CPU module.
Make 2 turns around the ferrite core and attach within approximately 200 mm from the terminal block and connectors of the
power cable. Also, attach a ferrite core to the input/output cable pulled out to the outside of the control panel. Attach the ferrite
core before the cable is pulled out to the outside of the control panel. (Ferrite core used in Mitsubishi Electric's test:
E04SR401938 manufactured by SEIWA ELECTRIC MFG. CO., LTD.)
APPX
278

Appendix 6 Standards

Standards
FX5-4DA
Remarks
Compliance with all relevant aspects of the standard.
EMI
• Radiated emission
• Conducted emission
EMS
• Radiated electromagnetic field
• Fast transient burst
• Electrostatic discharge
• High-energy surge
• Voltage drops and interruptions
• Conducted RF
• Power frequency magnetic field

Advertisement

Table of Contents
loading

Table of Contents