■Default value
The default value is Disable (1) for all the channels.
CH1 Scaling upper limit value
Set an upper limit value for the range of the scale conversion.
For details on the scaling function, refer to the following.
Page 34 Scaling function
■Buffer memory address
The following shows the buffer memory address of this area.
Buffer memory name
CH Scaling upper limit value
CH Scaling upper limit value (In FX3
allocation mode function)
■Setting range
The possible setting range is from -2147483648 to +2147483647.
In the channel where a set value does not satisfy the condition "the scaling upper limit value  the scaling lower limit value", a
scaling upper/lower limit value setting error (error code: 1A2H) occurs.
When 'CH1 Scaling enable/disable setting' (Un\G504) is set to Disable (1), the setting for 'CH1 Scaling upper limit value'
(Un\G506, 507) is ignored.
■Enabling the setting
Turn offonoff 'Operating condition setting request' (Un\G70, b9) to enable the setting.
■Default value
The default value is 0 for all channels.
CH1 Scaling lower limit value
Set a lower limit value for the range of the scale conversion.
For details on the scaling function, refer to the following.
Page 34 Scaling function
■Buffer memory address
The following shows the buffer memory address of this area.
Buffer memory name
CH Scaling lower limit value
CH Scaling lower limit value (In FX3 allocation
mode function)
■Setting range
The possible setting range is from -2147483648 to +2147483647.
In the channel where a set value does not satisfy the condition "the scaling upper limit value  the scaling lower limit value", a
scaling upper/lower limit value setting error (error code: 1A2H) occurs.
When 'CH1 Scaling enable/disable setting' (Un\G504) is set to Disable (1), the setting for 'CH1 Scaling lower limit value'
(Un\G508, 509) is ignored.
■Enabling the setting
Turn offonoff 'Operating condition setting request' (Un\G70, b9) to enable the setting.
■Default value
The default value is 0 for all channels.
CH1
CH2
506, 507
706, 707
1100, 1101
1102, 1103
CH1
CH2
508, 509
708, 709
1120, 1121
1122, 1123
CH3
CH4
906, 907
1106, 1107
1104, 1105
1106, 1107
CH3
CH4
908, 909
1108, 1109
1124, 1125
1126, 1127
Appendix 4 Buffer Memory Areas
A
APPX
155