Download  Print this page

List Of Error Codes - Mitsubishi Electric MELSEC iQ-F FX5 User Manual

Analog control - intelligent function module.
Hide thumbs
   
1
2
3
4
5
6
7
8
9
Table of Contents
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
337
338
339
340
341
342
343
344
345
346
347
348
349
350
351
352
353
354
355
356
357
358
359
360
361
362
363
364
365
366
367
368
369
370
371
372
373
374
375
376
377
378
379
380
381
382
383
384
385
386
387
388
389
390
391
392
393
394
395
396
397
398
399
400
401
402
403
404
405
406
407
408
409
410
411
412
413
414
415
416
417
418
419
420
421
422
423
424
425
426
427
428
429
430
431
432
433
434
435
436
437
438
439
440
441
442
443
444
445
446
447
448
449
450
451
452
453
454
455
456
457
458
459
460
461
462
463
464
465
466
467
468
469
470
471
472
473
474
475
476
477
478
479
480
481
482
483
484
485
486
487
488
489
490
491
492
493
494
495
496

Advertisement

List of error codes

If an error occurs during operation, an analog output module stores the error code into 'Latest error code' (Un\G0) of the buffer
memory In addition, 'Error flag' (Un\G69, b15) turns on. Turning on 'Error clear request' (Un\G70, b15) clears the error code in
'Latest error code' (Un\G0) and turns off 'Error flag' (Un\G69, b15).
Error codes of an analog output module are classified into minor and moderate errors.
• Minor error: This error is caused by the setting failure of programs and parameters, and after eliminating the error cause,
each function normally executes. (1000H to 1FFFH)
• Moderate error: An error such as hardware failure. The D/A conversion does not continue. (3000H to 3FFFH)
The following table lists the error codes that may be stored.
: Indicates the number of the channel where an error has occurred. It represents one of numerical values 0 to 3, which
correspond to CH1 to CH4.
(CH1: 0, CH2: 1, CH3: 2, CH4: 3)
 in error code: Indicates the interrupt setting corresponding to the error (0: setting 1 to F: setting 16).
Error code
Error name
0000H
1080H
Number of writes to offset/gain
settings reach limit error
180H
Interrupt factor transaction
setting range error
181H
Condition target setting range
error
182H
Condition target channel
setting range error
1861H
Offset/gain setting continuous
write occurrence error
190H
Range setting range error
191H
Digital value setting range
error
192H
HOLD setting value range
error
1A0H
Scaling enable/disable setting
range error
1A2H
Scaling upper/lower limit value
setting error
1B0H
Warning output setting range
error
1B1H
Warning output upper/limit
reversal error
1B8H
Rate control enable/disable
setting range error
1B9H
Digital limit value range error
Description and cause
There is no error.
The number of the offset/gain settings has
exceeded the guaranteed maximum number.
A value other than 0 or 1 was set in 'Interrupt factor
transaction setting' (Un\G200 to 215).
A value other than 0 to 4 was set in 'Condition target
setting' (Un\G232 to 247).
A value other than 0 to 4 was set in 'Condition target
channel setting' (Un\G264 to 279).
The setting value has been continuously written to
the flash memory 26 times or more in the offset/gain
setting.
A value out of the range is set in CH Range
setting.
• For normal output
A value out of the range is set for the CH Digital
value.
• For wave output
A value out of the setting range was set for part of
'wave data registry area' (Un\G10000 to
Un\G89999) used for the channel of wave-output-in-
progress.
A value out of the range is set in CH HOLD
setting.
A value other than 0 and 1 is set in CH Scaling
enable/disable setting.
CH Scaling upper limit value and CH Scaling
lower limit value are set as the scaling upper limit
value = the scaling lower limit value.
A value other than 0 to 2 was set in CH Warning
output setting.
A value not meeting the following condition was set
for the CH Warning output upper limit value or
CH Warning output lower limit value.
Upper limit value > Lower limit value
A value other than 0 or 1 was set in CH Rate
control enable/disable setting.
A value other than 0 to 64000 was set for the CH
Increase digital limit value or CH Decrease digital
limit value.
Corrective action
Though any further setting of offset/gain values
is performed, the setting value will not be
guaranteed.
Retry to set 0 or 1 in 'Interrupt factor transaction
setting' (Un\G200 to 215).
Retry to set a value of 0 to 4 in 'Condition target
setting' (Un\G232 to 247).
Retry to set a value of 0 to 4 in 'Condition target
channel setting' (Un\G264 to 279).
For the offset/gain setting, write the setting
value only once per setting.
Set CH Range setting to the value within the
range again.
Retry to set a proper value for the CH Digital
value.
Correct the corresponding data in 'wave data
registry area' (Un\G10000 to Un\G89999) being
used for the channel where the error occurred,
to a value within the setting range.
Retry to set a proper value for the CH HOLD
digital value.
Set CH Scaling enable/disable setting to 0 or
1.
Set CH Scaling upper limit value and CH
Scaling lower limit value as the scaling upper
limit value  the scaling lower limit value.
Retry to set CH Warning output setting to 0 to
2.
Retry to set the CH Warning output upper limit
value and CH Warning output lower limit
value so that the condition "upper limit value >
lower limit value".
Retry to set CH Rate control enable/disable
setting to 0 or 1.
Retry to set a value of 0 to 64000 for the CH
Increase digital limit value or CH Decrease
digital limit value.
2 FX5-4DA
2.10 Troubleshooting
2
273

Advertisement

Table of Contents

Comments to this Manuals

Symbols: 0
Latest comments: