Mitsubishi Electric MELSEC iQ-F FX5 User Manual Page 413

Analog control - intelligent function module.
Hide thumbs
   
1
2
3
4
5
6
7
8
9
Table of Contents
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
337
338
339
340
341
342
343
344
345
346
347
348
349
350
351
352
353
354
355
356
357
358
359
360
361
362
363
364
365
366
367
368
369
370
371
372
373
374
375
376
377
378
379
380
381
382
383
384
385
386
387
388
389
390
391
392
393
394
395
396
397
398
399
400
401
402
403
404
405
406
407
408
409
410
411
412
413
414
415
416
417
418
419
420
421
422
423
424
425
426
427
428
429
430
431
432
433
434
435
436
437
438
439
440
441
442
443
444
445
446
447
448
449
450
451
452
453
454
455
456
457
458
459
460
461
462
463
464
465
466
467
468
469
470
471
472
473
474
475
476
477
478
479
480
481
482
483
484
485
486
487
488
489
490
491
492
493
494
495
496

Advertisement

■When the ERROR LED turns on or flashes
• When it is on
Check item
Check whether any error has occurred.
• When flashing
Check item
Check whether 24 V DC external supply power shutdown has occurred.
■When the ALM LED turns on or flashes
• When it is on
Check item
Check whether any alert has been issued.
• When flashing
Check item
Check whether any input signal error has occurred.
■When a digital output value cannot be read
Check item
Check whether an analog signal line is disconnected from the multiple input
module.
Check whether the CPU module is in the STOP state.
Check whether the offset/gain setting in the user range setting is correct.
Check whether the input type/input range setting are correct.
Check whether 'Operating condition setting request' (Un\G70, b9) has been
executed.
Check whether the setting value of the time average is correct when the time
average is selected in Averaging process specification.
*1 The conversion does not start when 'Operating condition setting request' (Un\G70, b9) is on. After turning offon, check that 'Operating
condition setting completed flag' (Un\G69, b9) is off, and then make sure to turn onoff.
■When the digital output value does not fall within the range of accuracy
Check item
Check whether any measures have been taken to reduce noise.
Is an external input being made to a conversion disabled channel?
Corrective action
Check 'Latest error code' (Un\G0) and take actions described in the list of
error codes.
Page 414 List of error codes
Corrective action
Check that FX5-8AD and 24 V DC external power supply are properly
connected.
Additionally, before turning on the system power supply, check that the voltage
supply from the 24 V DC external power supply is started to FX5-8AD.
Corrective action
Check Alert output flag (Process alarm upper limit), Alert output flag (Process
alarm lower limit), Alert output flag (Rate alarm upper limit), and Alert output
flag (Rate alarm lower limit).
Take actions described in the list of alarm codes.
Page 417 List of alarm codes
Corrective action
Check Input signal error detection signal or Input signal error detection flag.
Take actions described in the list of alarm codes.
Page 417 List of alarm codes
Corrective action
Visually check signal lines and correctly connect analog signal lines.
Change the state of the CPU module to RUN.
Check that the offset/gain setting is correct.
If the user range setting is selected, change the other input range to the
factory shipment setting, and check that the conversion is performed.
Reconfigure the offset/gain setting when the conversion is correct.
Check CH Input type/Range monitor with GX Works3. When the input type/
input range setting are incorrect, reconfigure the input type and input range
setting again.
*1
Turn offonoff
'Operating condition setting request' (Un\G70, b9) and
check that a digital output value is stored in 'CH1 Digital output value'
(Un\G400) using GX Works3. If the stored value is correct, check the program.
When the time average is selected for processing, set the time average value
in CH1 Time average/Count average/Moving average setting so that the value
satisfies the following condition:
• Time average setting value  4 (times)  1 (ms)  Number of input type
current/voltage specified channel
If the condition above is not satisfied, the digital output value results in 0.
Corrective action
To reduce noise, take measures such as the use of shielded cables for
connection.
Do not input to a conversion disabled channel from an external device.
3 FX5-8AD
411
3.10 Troubleshooting