YASKAWA SGD7S-****20A Series Product Manual page 516

Servopack with mechatrolink-iii communications references, ac servo drive
Table of Contents

Advertisement

Parameter
Name
No.
Communications Con-
2
trols
MECHATROLINK Communications Check Mask for Debugging

n.
X
Warning Check Masks
Pn800

n.
X

n.
X
Reserved parameter (Do not change.)
Automatic Warning Clear Selection for Debugging

n.X
*9
M3
Application Function
2
Selections 6 (Software
Limits)
Software Limit Selection

n.
X
Pn801

n.
X
Reserved parameter (Do not change.)
Software Limit Check for References

n.
X

n.X
Reserved parameter (Do not change.)
Pn803
2
Origin Range
Pn804
4
Forward Software Limit
Setting
Setting
Range
Unit
0000h to
1FF3h
0
Do not mask.
1
Ignore MECHATROLINK communications errors (A.E60).
2
Ignore WDT errors (A.E50).
Ignore both MECHATROLINK communications errors (A.E60) and WDT
3
errors (A.E50).
0
Do not mask.
1
Ignore data setting warnings (A.94).
2
Ignore command warnings (A.95).
3
Ignore both A.94 and A.95 warnings.
4
Ignore communications warnings (A.96).
5
Ignore both A.94 and A.96 warnings.
6
Ignore both A.95 and A.96 warnings.
7
Ignore A.94, A.95, and A.96 warnings.
8
Ignore data setting warnings (A.97A and A.97b).
9
Ignore A.94, A.97A, and A.97b warnings.
A
Ignore A.95, A.97A, and A.97b warnings.
B
Ignore A.94, A.95, A.97A, and A.97b warnings.
C
Ignore A.96, A.97A, and A.97b warnings.
D
Ignore A.94, A.96, A.97A, and A.97b warnings.
E
Ignore A.95, A.96, A.97A, and A.97b warnings.
F
Ignore A.94, A.95, A.96, A.97A, and A.97b warnings.
0
Retain warnings for debugging.
1
Automatically clear warnings (MECHATROLINK-III specification).
0000h to
0103h
0
Enable both forward and reverse software limits.
1
Disable forward software limit.
2
Disable reverse software limit.
3
Disable both forward and reverse software limits.
0
Do not perform software limit checks for references.
1
Perform software limit checks for references.
1 refer-
0 to 250
ence
unit
-1,073,741,823
1 refer-
to
ence
1,073,741,823
unit
13.1 List of Servo Parameters
13.1.2 List of Servo Parameters
Continued from previous page.
Default
Applicable
When
Setting
Motors
Enabled
Immedi-
1040h
All
ately
*9
Immedi-
0003h
All
ately
Immedi-
10
All
ately
107374
Immedi-
All
1823
ately
Continued on next page.
Classi-
Refer-
fication
ence
Setup
page
Setup
6-27
Setup
*1
13
page
Setup
6-27
13-29

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sigma-7-s series

Table of Contents