Functions - YASKAWA SGD7S-****20A Series Product Manual

Servopack with mechatrolink-iii communications references, ac servo drive
Table of Contents

Advertisement

2.1 Ratings and Specifications
2.1.3 Specifications
Displays/Indicators
MECHA-
TROLINK-III
Communi-
cations
Reference
Method
MECHATROLINK-III Communica-
tions Setting Switches
Analog Monitor (CN5)
Dynamic Brake (DB)
Regenerative Processing
Overtravel (OT) Prevention
Protective Functions
Utility Functions
Safety

Functions

Applicable Option Modules
If you combine a Σ-7-Series SERVOPACK with a Σ-V-Series Option Module, the following Σ-V-Series SERVO-
*1.
PACKs specifications must be used: a surrounding air temperature of 0°C to 55°C and an altitude of 1,000 m
max. Also, the applicable surrounding range cannot be increased by derating.
*2.
The coefficient of speed fluctuation for load fluctuation is defined as follows:
Coefficient of peed fluctuation = No-load motor peed - Total-load motor peed
*3.
Always perform risk assessment for the system and confirm that the safety requirements are met.
2-8
Item
CHARGE, PWR, CN, L1, and L2 indicators, and one-digit seven-seg-
ment display
Communications Pro-
MECHATROLINK-III
tocol
03h to EFh (maximum number of slaves: 62)
Station Address
Settings
The rotary switches (S1 and S2) are used to set the station address.
Transmission Speed
100 Mbps
125 μs, 250 μs, 500 μs, 750 μs,
Transmission Cycle
1.0 ms to 4.0 ms (multiples of 0.5 ms)
32 or 48 bytes/station
Number of Transmis-
sion Bytes
A DIP switch (S3) is used to select the number of transmission bytes.
Position, speed, or torque control with MECHATROLINK-III communi-
Performance
cations
MECHATROLINK-III commands (sequence, motion, data setting, data
Reference Input
access, monitoring, adjustment, etc.)
MECHATROLINK-III standard servo profile
Profile
Rotary switch (S1 and S2) positions: 16
Number of DIP switch (S3) pins: 4
Number of points: 2
Output voltage range: ±10 VDC (effective linearity range: ±8 V)
Resolution: 16 bits
Accuracy: ±20 mV (Typ)
Maximum output current: ±10 mA
Settling time (±1%): 1.2 ms (Typ)
Activated when a servo alarm or overtravel (OT) occurs, or when the
power supply to the main circuit or servo is OFF.
Built-in (An external resistor must be connected to the SGD7S-470A to
-780A.)
Refer to the following catalog for details.
Stopping with dynamic brake, deceleration to a stop, or coasting to a
stop for the P-OT (Forward Drive Prohibit) or N-OT (Reverse Drive Pro-
hibit) signal
Overcurrent, overvoltage, low voltage, overload, regeneration error, etc.
Gain adjustment, alarm history, jogging, origin search, etc.
Inputs
/HWBB1 and /HWBB2: Base block signals for Power Modules
Output
EDM1: Monitors the status of built-in safety circuit (fixed output).
Applicable
ISO13849-1 PLe (Category 3), IEC61508 SIL3
*3
Standards
Fully-closed Modules and Safety Modules
Note: You cannot use a Fully-closed Module and a Safety Module together.
Specification
AC Servo Drives Σ-7 Series (Catalog No.: KAEP S800001 23)
Rated motor peed
Continued from previous page.
×
100%

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sigma-7-s series

Table of Contents