Parameter
Name
No.
Input Signal Selections
2
2
N-OT (Reverse Drive Prohibit) Signal Allocation
n.
X
n.
X
Reserved parameter (Do not change.)
Pn50B
/P-CL (Forward External Torque Limit Input) Signal Allocation
n.
X
/N-CL (Reverse External Torque Limit Input) Signal Allocation
n.X
Setting
Setting
Range
Unit
0000h to
–
FFFFh
0
Enable reverse drive when CN1-13 input signal is ON (closed).
1
Enable reverse drive when CN1-7 input signal is ON (closed).
2
Enable reverse drive when CN1-8 input signal is ON (closed).
3
Enable reverse drive when CN1-9 input signal is ON (closed).
4
Enable reverse drive when CN1-10 input signal is ON (closed).
5
Enable reverse drive when CN1-11 input signal is ON (closed).
6
Enable reverse drive when CN1-12 input signal is ON (closed).
7
Set the signal to always prohibit reverse drive.
8
Set the signal to always enable reverse drive.
9
Enable reverse drive when CN1-13 input signal is OFF (open).
A
Enable reverse drive when CN1-7 input signal is OFF (open).
B
Enable reverse drive when CN1-8 input signal is OFF (open).
C
Enable reverse drive when CN1-9 input signal is OFF (open).
D
Enable reverse drive when CN1-10 input signal is OFF (open).
E
Enable reverse drive when CN1-11 input signal is OFF (open).
F
Enable reverse drive when CN1-12 input signal is OFF (open).
0
Active when CN1-13 input signal is ON (closed).
1
Active when CN1-7 input signal is ON (closed).
2
Active when CN1-8 input signal is ON (closed).
3
Active when CN1-9 input signal is ON (closed).
4
Active when CN1-10 input signal is ON (closed).
5
Active when CN1-11 input signal is ON (closed).
6
Active when CN1-12 input signal is ON (closed).
7
The signal is always active.
8
The signal is always inactive.
9
Active when CN1-13 input signal is OFF (open).
A
Active when CN1-7 input signal is OFF (open).
B
Active when CN1-8 input signal is OFF (open).
C
Active when CN1-9 input signal is OFF (open).
D
Active when CN1-10 input signal is OFF (open).
E
Active when CN1-11 input signal is OFF (open).
F
Active when CN1-12 input signal is OFF (open).
The allocations are the same as the /P-CL (Forward External
0 to F
Torque Limit Input) signal allocations.
13.1 List of Servo Parameters
13.1.2 List of Servo Parameters
Continued from previous page.
Default
Applicable
When
Setting
Motors
Enabled
After
8882h
All
restart
Continued on next page.
Classi-
Refer-
fication
ence
Setup
–
Reference
page 5-29
Reference
page 6-29
Reference
page 6-29
13
13-21