13.1 List of Servo Parameters
13.1.2 List of Servo Parameters
Parameter
No.
Pn52C
Pn530
Pn531
Pn533
Pn534
Pn535
Pn536
Pn550
Pn551
Pn552
Pn553
Pn55A
Pn560
Pn561
13-26
Name
Base Current Derating
2
at Motor Overload
Detection
Program Jogging-
2
Related Selections
Program Jogging Operation Pattern
(Waiting time in Pn535 → Forward by travel distance in Pn531) × Number of
0
movements in Pn536
(Waiting time in Pn535 → Reverse by travel distance in Pn531) × Number of
1
movements in Pn536
(Waiting time in Pn535 → Forward by travel distance in Pn531) × Number of
movements in Pn536
2
(Waiting time in Pn535 → Reverse by travel distance in Pn531) × Number of
movements in Pn536

n.
X
(Waiting time in Pn535 → Reverse by travel distance in Pn531) × Number of
movements in Pn536
3
(Waiting time in Pn535 → Forward by travel distance in Pn531) × Number of
movements in Pn536
(Waiting time in Pn535 → Forward by travel distance in Pn531 → Waiting time
in Pn535 → Reverse by travel distance in Pn531) × Number of movements in
4
Pn536
(Waiting time in Pn535 → Reverse by travel distance in Pn531 → Waiting time
in Pn535 → Forward by travel distance in Pn531) × Number of movements in
5
Pn536

n.
X
Reserved parameter (Do not change.)

n.
X
Reserved parameter (Do not change.)

n.X
Reserved parameter (Do not change.)
Program Jogging Travel
4
Distance
Program Jogging Move-
2
ment Speed
Program Jogging Accel-
2
eration/Deceleration
Time
Program Jogging Wait-
2
ing Time
Program Jogging Num-
2
ber of Movements
Analog Monitor 1 Offset
2
Voltage
Analog Monitor 2 Offset
2
Voltage
Analog Monitor 1 Mag-
2
nification
Analog Monitor 2 Mag-
2
nification
Power Consumption
2
Monitor Unit Time
Residual Vibration
2
Detection Width
Overshoot Detection
2
Level
Setting
Setting
Default
Range
Unit
Setting
10 to 100
1%
100
0000h to
0000h
0005h
1 refer-
1 to
ence
32768
1,073,741,824
unit
Rotary:
-1
1 min
1 to 10,000
Direct
500
Drive:
-1
0.1 min
2 to 10,000
1 ms
100
0 to 10,000
1 ms
100
0 to 1,000
1 time
1
-10,000 to
0.1 V
0
10,000
-10,000 to
0.1 V
0
10,000
-10,000 to
× 0.01
100
10,000
-10,000 to
× 0.01
100
10,000
1 to 1,440
1 min
1
1 to 3,000
0.1%
400
0 to 100
1%
100
Continued from previous page.
Applicable
When
Classi-
Motors
Enabled
fication
After
All
Setup
restart
Immedi-
All
Setup
ately
Immedi-
All
Setup
ately
Immedi-
Rotary
Setup
ately
Immedi-
All
Setup
ately
Immedi-
All
Setup
ately
Immedi-
All
Setup
ately
Immedi-
All
Setup
ately
Immedi-
All
Setup
ately
Immedi-
All
Setup
ately
Immedi-
All
Setup
ately
Immedi-
All
Setup
ately
Immedi-
All
Setup
ately
Immedi-
All
Setup
ately
Continued on next page.
Refer-
ence
page
5-41
page
7-14
page
7-14
page
7-14
page
7-14
page
7-14
page
7-14
page
9-10
page
9-10
page
9-10
page
9-10
page
8-56
page
8-31,
page
8-40