12.2 Alarm Displays
12.2.2 Troubleshooting Alarms
Alarm Number:
Alarm Name
A.8A5:
External Encoder
Overspeed
A.8A6:
External Encoder
Overheated
A.b33:
Current Detec-
tion Error 3
A.b6A:
MECHATROLINK
Communications
ASIC Error 1
A.b6b:
MECHATROLINK
Communications
ASIC Error 2
A.bF0:
System Alarm 0
A.bF1:
System Alarm 1
A.bF2:
System Alarm 2
A.bF3:
System Alarm 3
12-28
Possible Cause
An overspeed error
Check the maximum
was detected in the
speed of the external
external encoder.
encoder.
An overheating error
was detected in the
external encoder.
A failure occurred in
the current detection
circuit.
There is a fault in the
SERVOPACK
MECHATROLINK
communications sec-
tion.
A malfunction
occurred in the
MECHATROLINK
communications sec-
tion due to noise.
There is a fault in the
SERVOPACK
MECHATROLINK
communications sec-
tion.
A failure occurred in
the SERVOPACK.
A failure occurred in
the SERVOPACK.
A failure occurred in
the SERVOPACK.
A failure occurred in
the SERVOPACK.
Confirmation
Keep the external
encoder below its maxi-
mum speed.
Replace the external
encoder.
Turn the power supply to
the SERVOPACK OFF and
ON again. If an alarm still
occurs, the SERVOPACK
may be faulty. Replace the
SERVOPACK.
Turn the power supply to
the SERVOPACK OFF and
ON again. If an alarm still
occurs, the SERVOPACK
may be faulty. Replace the
SERVOPACK.
Implement the following
countermeasures against
noise.
• Check the MECHA-
TROLINK Communica-
tions Cable and FG
wiring.
• Attach a ferrite core to
the MECHATROLINK
Communications Cable.
Turn the power supply to
the SERVOPACK OFF and
ON again. If an alarm still
occurs, the SERVOPACK
may be faulty. Replace the
SERVOPACK.
Turn the power supply to
the SERVOPACK OFF and
ON again. If an alarm still
occurs, the SERVOPACK
may be faulty. Replace the
SERVOPACK.
Turn the power supply to
the SERVOPACK OFF and
ON again. If an alarm still
occurs, the SERVOPACK
may be faulty. Replace the
SERVOPACK.
Turn the power supply to
the SERVOPACK OFF and
ON again. If an alarm still
occurs, the SERVOPACK
may be faulty. Replace the
SERVOPACK.
Turn the power supply to
the SERVOPACK OFF and
ON again. If an alarm still
occurs, the SERVOPACK
may be faulty. Replace the
SERVOPACK.