8.4.4
Parameters Disabled by Tuning-less Function
When the tuning-less function is enabled (Pn170 = n.1) (default setting), the parameters
in the following table are disabled.
Gain-Related Parameters
Advanced Control-Related
Parameters
Gain Selection-Related Parameters
The tuning-less function is disabled during torque control, Easy FFT, and mechanical analysis
for a vertical axis. The gain-related parameters in the above table are enabled for torque con-
trol, Easy FFT, and mechanical analysis. Of these, Pn100, Pn103, and Pn104 are enabled for
torque control.
8.4.5
Automatically Adjusted Function Setting
You can also automatically adjust notch filters.
Normally, set Pn460 to n.1 (Adjust automatically) (default setting). Vibration is automati-
cally detected and a notch filter is set.
Set Pn460 to n.0 (Do not adjust automatically) only if you do not change the setting of
the notch filter before you execute the tuning-less function.
Parameter
n.
0
Pn460
n.
1
(default setting)
8.4.6
Related Parameters
The following parameters are automatically adjusted when you execute the tuning-less func-
tion.
Do not manually change the settings of these parameters after you have enabled the tuning-
less function.
Parameter
Pn401
Pn40C
Pn40D
Item
Speed Loop Gain
Second Speed Loop Gain
Speed Loop Integral Time Constant
Second Speed Loop Integral Time Constant
Position Loop Gain
Second Position Loop Gain
Moment of Inertia Ratio
Friction Compensation Function Selection
Anti-Resonance Control Selection
Gain Switching Selection
Do not adjust the second stage notch filter
automatically during execution of autotuning
without a host reference, autotuning with a
host reference, and custom tuning.
Adjust the second stage notch filter automati-
cally during execution of autotuning without a
host reference, autotuning with a host refer-
ence, and custom tuning.
Name
First Stage First Torque Reference Filter Time Constant
Second Stage Notch Filter Frequency
Second Stage Notch Filter Q Value
8.4.4 Parameters Disabled by Tuning-less Function
Parameter Name
Meaning
8.4 Tuning-less Function
Parameter Number
Pn100
Pn104
Pn101
Pn105
Pn102
Pn106
Pn103
Pn408 = n.X
Pn160= n.
Pn139= n.
When Enabled
Classification
Immediately
Tuning
X
X
8