9.3 Monitoring Machine Operation Status and Signal Waveforms
9.3.3 Using the Analog Monitors
• Gain Adjustment
Digital Operator
SigmaWin+
 Operating Procedure
Use the following procedure to adjust the analog monitor output.
1.
Click the
maWin+.
2.
Select Adjust the Analog Monitor Output in the Menu Dialog Box.
The Adjust the Analog Monitor Output Dialog Box will be displayed.
3.
Click the Zero Adjustment or Gain Adjustment Tab.
4.
While watching the analog monitor, use the +1 and -1 Buttons to adjust the offset.
There are two channels: CH1 and CH2. If necessary, click the down arrow on the Channel Box and
select the channel.
This concludes adjusting the analog monitor output.
9-12
Tool
Function
Fn00D
Setup - Analog Monitor Out-
put Adjustment
Servo Drive Button in the workspace of the Main Window of the Sig-
Operating Procedure Reference
Σ-7-Series Digital Operator Operating Manual
(Manual No.: SIEP S800001 33)
Operating Procedure on page 9-12