8.13 Manual Tuning
8.13.2 Compatible Adjustment Functions
Using the Torque Reference as the Mode Switching Condition (Default Setting)
When the torque reference equals or exceeds the torque set for the mode switching level for
torque reference (Pn10C), the speed loop is changed to P control.
The default setting for the torque reference level is 200%.
Torque reference 0
Using the Speed Reference as the Mode Switching Condition
• Rotary Servomotors
When the speed reference equals or exceeds the speed set for the mode switching level for a
speed reference (Pn10D), the speed loop is changed to P control.
peed
Pn10D
• Linear Servomotors
When the speed reference equals or exceeds the speed set for the mode switching level for a
speed reference (Pn181), the speed loop is changed to P control.
peed
Pn181
8-94
peed reference
peed
Torque reference
+Pn10C
- Pn10C
PI control
PI
P
peed reference
Motor peed
PI
P control
peed reference
Motor peed
PI
P control
Motor peed
Time
PI control
P
Time
PI control
Time
PI control