Operation Manual – NTP
H3C S3610&S5510 Series Ethernet Switches
[SwitchA-Vlan-interface3] ntp-service multicast-client
# View the NTP status of Switch A after clock synchronization.
[SwitchA] display ntp-service status
Clock status: synchronized
Clock stratum: 3
Reference clock ID: 3.0.1.31
Nominal frequency: 100.0000 Hz
Actual frequency: 100.0000 Hz
Clock precision: 2^7
Clock offset: 0.0000 ms
Root delay: 40.00 ms
Root dispersion: 10.83 ms
Peer dispersion: 34.30 ms
Reference time: 16:02:49.713 UTC Apr 20 2007 (C6D95F6F.B6872B02)
As shown above, Switch A has been synchronized to Switch C, and the clock stratum
level of Switch A is 3, while that of Switch C is 2.
# View the NTP session information of Switch A, which shows that an association has
been set up between Switch A and Switch C.
[SwitchA] display ntp-service sessions
source
**************************************************************************
[1234] 3.0.1.31
note: 1 source(master),2 source(peer),3 selected,4 candidate,5 configured
Total associations :
Note:
Refer to the Multicast Protocol part of the manual for detailed description of the
multicast function.
1.8.5 Configuring NTP Server/Client Mode with Authentication
I. Network requirements
The local clock of Device A is to be configured as a reference source, with the
stratum level of 2.
Device B works in the client mode and Device A is to be used as the NTP server of
Device B, with Device B as the client.
NTP authentication is to be enabled for Device A and Device B at the same time.
reference
stra
reach
127.127.1.0
2
1
1-26
Chapter 1 NTP Configuration
poll
now
offset
255
64
26
delay
disper
-16.0
40.0
16.6