Operation Manual – NQA
H3C S3610&S5510 Series Ethernet Switches
2)
Configure the NQA client
Follow these steps to configure NQA client for the TCP test:
Enter system view
Enable the NQA client
Create an NQA test group
and enter its view
Set the test type to TCP
Configure a destination
address for a test
Configure a destination
port
Configure common
optional parameters
Enable the NQA test
View the test results
II. Configuration example
1)
Network requirements
Use the NQA TCP-Private function to test the time for setting up a TCP connection
between the local port (Switch A) and the specified destination port (Switch B). The port
number used is 9000.
To do...
system-view
nqa-agent enable
nqa admin-name
operation-tag
test-type { tcpprivate |
tcppublic }
destination-ip ip-address
destination-port
port-number
Configuring Optional
Parameters for NQA
Tests
test-enable
display nqa results
[ admin-name
operation-tag ]
Use the command...
1-20
Chapter 1 NQA Configuration
Remarks
—
Required
—
Required
Required
The destination address
must be the listening IP
address on the NQA
server.
If the test type is
TCP-Public, no port
needs to be configured. If
the test type is
TCP-Private, a port must
be configured and it must
be the listening port
configured on the NQA
server.
Optional
Required
Required
Available in any view.