Configuring The Periods And Thresholds For Oam Link Error Event Detection - H3C S3610-28P Operation Manual

S3610 & s5510 series
Table of Contents

Advertisement

Operation Manual – OAM
H3C S3610&S5510 Series Ethernet Switches
1.2.3 Configuring the Periods and Thresholds for OAM Link Error Event
Detection
Follow these steps to configure the periods and thresholds for OAM link error event
detection:
Enter system view
Configure the period for
error signal event
detection
Configure the threshold
for error signal event
detection
Configure the period for
error frame event
detection
Configure the threshold
for error frame event
detection
Configure the period for
frame-percentage error
event detection
Configure the threshold
for frame-percentage
error event detection
Configure the period for
second-percentage error
event detection
Configure the threshold
for second-percentage
error event detection
To do...
system-view
oam errored-symbol
period period-value
oam errored-symbol
threshold
threshold-value
oam errored-frame
period period-value
oam errored-frame
threshold
threshold-value
oam
errored-frame-period
period period-value
oam
errored-frame-period
threshold
threshold-value
oam
errored-frame-seconds
period period-value
oam
errored-frame-seconds
threshold
threshold-value
Use the command...
1-6
Chapter 1 OAM Configuration
Remarks
Optional
The default is one
second.
Optional
The default is 1.
Optional
The default is one
second.
Optional
The default is 1.
Optional
The default is 1,000
milliseconds.
Optional
The default is 1.
Optional
The default is 60 seconds.
Optional
The default is 1.
Make sure the threshold
for second-percentage
error event detection is
less than the period for
second-percentage error
event detection for
second-percentage error
events to be detected.

Advertisement

Table of Contents
loading

Table of Contents