Point Data Writing 2 (P_, S_, Ac_, Dc_, Q_) - Yamaha TS-S User Manual

Yamaha single-axis robot controller ts series
Table of Contents

Advertisement

Setting
<Point number> : 1 to 255
<Node number> : 1 to 16 (This setting can be omitted when the same command is sent to all the controllers connected
B
Communication example
@P1.1=30000 c/r l/f
@S1.1=50 c/r l/f
@AC1.1=100 c/r l/f
@DC1.1=50 c/r l/f
@M1.1=1 c/r l/f
Point data writing 2 (P_, S_, AC_, DC_, Q_)
Format
Meaning
Function
Writes the setting value to the individual data of a specified point. The written data is not saved into the memory.
The command may vary depending on the type of individual data. For details, see the table below.
Command and data type
n
n
NOTE
• Even when the setting value is written using this command, the value is not saved into the memory. So, the
value is returned to its previous value after the power has been turned off, and then turned on again. When
the setting value needs to be saved into the memory, it is necessary to write the operation type (M) after the
setting value has been written.
• The individual data of the point data related to the position or speed may include the decimal point due to
the specifications. However, when handling such data using the communication command, all of data are
handled as integer values. For example, when the position data is "20 [mm]", the communication command at
the TS-S, TS-S2, TS-SH, and TS-X would be "2000" (×10
"20000" (×10
• This command is valid from version 1.04.xxx or higher.
TIP
For point data details, see Chapter 3, section 2, "Point data" of the Controller Guide.
B-10
with the host device, as by daisy chain connection.)
Transmission
Response
OK.1 c/r l/f
OK.1 c/r l/f
OK.1 c/r l/f
OK.1 c/r l/f
OK.1 c/r l/f
@P_<point number>[.<node number>]=<setting value> c/r l/f
@S_<point number>[.<node number>]=<setting value> c/r l/f
@AC_<point number>[.<node number>]=<setting value> c/r l/f
@DC_<point number>[.<node number>]=<setting value> c/r l/f
@Q_<point number>[.<node number>]=<setting value> c/r l/f
Writes the setting value to the individual data of a specified point.
Command
P_
Position
S_
Speed
AC_
Acceleration
DC_
Deceleration
Q_
Push
-3
). In both cases, no decimal point is used.
Writes "30000" to "Position" of point data 1.
Normal end
Writes "50" to "Speed" of point data 1.
Normal end
Writes "100" to "Acceleration" of point data 1.
Normal end
Writes "50" to "Deceleration" of point data 1.
Normal end
Writes "1" (ABS) to "Operation type" of point data 1.
Normal end
Type
Standard Setting
-2
), and the communication command at the TS-P would be
Unit
Custom Setting
Other than TS-P
: 0.01mm
TS-P
: 0.001mm
%
0.01mm/s
%
0.01m/s
%
%
2

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ts-shTs-s2Ts-xTs-p

Table of Contents