Maintenance Console Location
9.27 PBX Configuration—[1-1] Configuration—Slot—Port Property - PRI Port
Status Message
Specifies whether the Status Message is sent to the network.
Default
No Transmission
Value Range
No Transmission: Status Message is not sent.
When error detection (Mandatory): Send the Status Message when an error (Mandatory) is detected.
When error detection (Option / Mandatory): Send the Status Message when an error (Option or Mandatory) is
detected.
Maintenance Console Location
9.27 PBX Configuration—[1-1] Configuration—Slot—Port Property - PRI Port
Status Receive
Selects what happens to a call when the Status Message from the network does not match the actual status
of the call.
Default
Ignore
Value Range
Ignore: Ignore the Status Message from the network.
Disconnect: Disconnect the call.
Maintenance Console Location
9.27 PBX Configuration—[1-1] Configuration—Slot—Port Property - PRI Port
Line Coding
Selects the line coding type of the PRI PCM (Pulse Code Modulation) for the port. This setting is only available
when using the PRI23 card.
Default
B8ZS
Value Range
B8ZS, AMI
Maintenance Console Location
9.27 PBX Configuration—[1-1] Configuration—Slot—Port Property - PRI Port