Panasonic KX-NS1000 Pc Programming Manual page 312

Pure ip-pbx
Hide thumbs Also See for KX-NS1000:
Table of Contents

Advertisement

9.11 PBX Configuration—[1-1] Configuration—Slot—V-SIPGW—Port Property
Maintenance Console Location
9.11 PBX Configuration—[1-1] Configuration—Slot—V-SIPGW—Port Property
Failover Timer(REGISTER)
Specifies the amount of time to wait for a response for a REGISTER request.
Note
If 0 is specified, failover operation follows the T1/T2 timer.
While monitoring failover with OPTIONS, the applicable timer setting is applied to OPTIONS as well.
This setting cannot be changed while the V-SIPGW16 card is set to INS.
This setting cannot be changed when an additional channel is active.
Default
0 s
Value Range
0–30 s
Maintenance Console Location
9.11 PBX Configuration—[1-1] Configuration—Slot—V-SIPGW—Port Property
Calling Party
The Shelf, Slot, and Port for each item are displayed for your reference. For details, see Common
Programming Reference Items in 9.1 PBX Configuration—[1-1] Configuration—Slot.
Connection
Indicates the port status. To change the status of the port, click the desired cell in the column, and then select
INS or OUS for the port.
This option is only available in On-line mode.
Default
INS
Value Range
INS: The port is in service.
OUS: The port is out of service.
Fault: The port is not communicating with the network.
Maintenance Console Location
9.11 PBX Configuration—[1-1] Configuration—Slot—V-SIPGW—Port Property
Header Type
Specifies the header of the SIP message in which the caller information is stored.
Default
From Header