Maintenance Console Location
9.12 PBX Configuration—[1-1] Configuration—Slot—V-IPGW16—Shelf Property
Voice Codec Priority 3rd
Specifies the third highest priority codec type.
Default
G.729A
Value Range
None, G.711A, G.711Mu, G.729A
Maintenance Console Location
9.12 PBX Configuration—[1-1] Configuration—Slot—V-IPGW16—Shelf Property
Packet Sampling Time for G.711A
Specifies the time interval between measurements (samples) of sound data during a conversation. The smaller
this number, the higher the quality of the transmitted sound.
Default
20 ms
Value Range
20 ms, 30 ms, 40 ms, 50 ms, 60 ms
Maintenance Console Location
9.12 PBX Configuration—[1-1] Configuration—Slot—V-IPGW16—Shelf Property
Packet Sampling Time for G.711Mu
Specifies the time interval between measurements (samples) of sound data during a conversation. The smaller
this number, the higher the quality of the transmitted sound.
Default
20 ms
Value Range
20 ms, 30 ms, 40 ms, 50 ms, 60 ms
Maintenance Console Location
9.12 PBX Configuration—[1-1] Configuration—Slot—V-IPGW16—Shelf Property
Packet Sampling Time for G.729A
Specifies the time interval between measurements (samples) of sound data during a conversation. The smaller
this number, the higher the quality of the transmitted sound.
Document Version 2016-03
9.12 PBX Configuration—[1-1] Configuration—Slot—V-IPGW16—Shelf Property
PC Programming Manual
341