Panasonic KX-NS1000 Pc Programming Manual page 916

Pure ip-pbx
Hide thumbs Also See for KX-NS1000:
Table of Contents

Advertisement

19.1 PBX Configuration—[11-1] Maintenance—Main
External Modem Command—Automatic Initialization
Specifies the command to automatically initialize an external modem when it is plugged into the Serial Interface
(RS-232C) port of the PBX.
Default
AT&F0Q0E0V1S0=1X0&D0
Value Range
Max. 30 characters
Maintenance Console Location
19.1 PBX Configuration—[11-1] Maintenance—Main
Maintenance
Local Alarm Display—Extension 1, Extension 2
Specifies the extension numbers of PTs that will be notified by the PBX about local alarms. When the PBX
detects a PBX error, the System Alarm button on the PT turns on red. When this button is pressed, the display
will show the error number, and the button light will turn off automatically.
Default
Not stored
Value Range
Max. 5 digits (consisting of 0–9)
Maintenance Console Location
19.1 PBX Configuration—[11-1] Maintenance—Main
Feature Manual References
12.1.4 Local Alarm Information
Daily Test Start Time—Set
Enables the daily self check of the PBX for local alarm and error log.
Default
Disable
Value Range
Disable, Enable
Maintenance Console Location
19.1 PBX Configuration—[11-1] Maintenance—Main
916
PC Programming Manual
Document Version 2016-03