SIP Extension

SIP Location Hold Time Max.
Specifies the maximum length of time that the PBX holds information on the location of SIP Extensions.
Default
320 s
Value Range
10–3600 s
Maintenance Console Location
9.16 PBX Configuration—[1-1] Configuration—Slot—V-SIPEXT32—Card Property
Feature Manual References
18.1.2 SIP (Session Initiation Protocol) Extension
SIP Location Hold Time Min.
Specifies the minimum length of time that the PBX holds information on the location of SIP Extensions.
Default
300 s
Value Range
10–3600 s
Maintenance Console Location
9.16 PBX Configuration—[1-1] Configuration—Slot—V-SIPEXT32—Card Property
Feature Manual References
18.1.2 SIP (Session Initiation Protocol) Extension
SIP Location Hold Time Interval
Specifies the interval time that the PBX waits before starting to hold information on location of SIP Extensions.
Default
1 s
Value Range
1–10 s
Maintenance Console Location
9.16 PBX Configuration—[1-1] Configuration—Slot—V-SIPEXT32—Card Property