Panasonic KX-NS1000 Pc Programming Manual page 222

Pure ip-pbx
Hide thumbs Also See for KX-NS1000:
Table of Contents

Advertisement

9.4 PBX Configuration—[1-1] Configuration—Slot—System Property
Master Suspend if Backup Master Detected
Specifies whether or not the Master unit enters suspended mode when it recovers from a fault, if it detects that
a Master Backup unit exists. If the Master unit is suspended, all extension and CO lines controlled by the Master
unit are unusable.
Default
Enable
Value Range
Enable (Master unit enters suspended mode)
Disable (Master unit does not enter suspended mode and resumes normal operation)
Maintenance Console Location
9.4 PBX Configuration—[1-1] Configuration—Slot—System Property
V-IPGW
Call Signaling Model
Specifies whether to carry out a call control (H.225) process directly between the cards or through a gatekeeper.
Default
Direct
Value Range
Direct, GateKeeper
Maintenance Console Location
9.4 PBX Configuration—[1-1] Configuration—Slot—System Property
Gatekeeper Connection Checking Interval (*60s)
Specifies the time between periodic checks of connection to the gatekeeper.
Default
0
Value Range
0 (disabled), 1–1440
Maintenance Console Location
9.4 PBX Configuration—[1-1] Configuration—Slot—System Property
Terminal type to Gatekeeper
Specifies the connection service type notified to the gatekeeper.
Default
Terminal