9.17 PBX Configuration—[1-1] Configuration—Slot—V-SIPEXT32—Port Property
Packet Sampling Time (G.729A)
Specifies the time interval between measurements (samples) of sound data during a conversation. The smaller
this number, the higher the quality of the transmitted sound.
Default
20 ms
Value Range
20 ms, 30 ms, 40 ms, 50 ms, 60 ms
Maintenance Console Location
9.17 PBX Configuration—[1-1] Configuration—Slot—V-SIPEXT32—Port Property
Feature Manual References
18.1.2 SIP (Session Initiation Protocol) Extension
Remote Place
The Shelf, Slot, and Port for each item are displayed for your reference. For details, see Common
Programming Reference Items in 9.1 PBX Configuration—[1-1] Configuration—Slot.
Extension Number
Specifies the extension number of the port.
Default
Starting at 101
Value Range
Max. 5 digits (consisting of 0–9)
Maintenance Console Location
9.17 PBX Configuration—[1-1] Configuration—Slot—V-SIPEXT32—Port Property
Feature Manual References
18.1.2 SIP (Session Initiation Protocol) Extension
Password
Specifies the password used for registering a SIP Extension to the PBX. While it is possible to enter a password
manually for each SIP Extension, you can copy the value for
the Copy to button. This parameter can only be modified when the virtual SIP extension port is set to OUS,
and the programmer must be in On-line mode.
Default
Not stored