Panasonic KX-NS1000 Pc Programming Manual page 252

Pure ip-pbx
Hide thumbs Also See for KX-NS1000:
Table of Contents

Advertisement

9.5.1 PBX Configuration—[1-1] Configuration—Slot—Site Property—Main
Maintenance Console Location
9.5 PBX Configuration—[1-1] Configuration—Slot—Site Property
Feature Manual References
10.1.17 IP-PT (IP Proprietary Telephone)
Voice (RTP) UDP Port No. (IP-PT / SIP-MLT)
Specifies the UDP port used to transmit and receive RTP (Real-time Transfer Protocol) data on the IP-PT side.
This must be changed if another network application is using the same port.
For voice communications, an IP-PT uses 128 contiguous UDP ports, starting from the port number specified
here.
To change the value displayed here, click Common Settings and set the desired value.
Default
8000
Value Range
1024–65535
Maintenance Console Location
9.5 PBX Configuration—[1-1] Configuration—Slot—Site Property
Feature Manual References
10.1.17 IP-PT (IP Proprietary Telephone)
UDP Port No. for SIP Extension Server
Specifies the UDP port number used for the SIP Extension server.
To change the value displayed here, click Common Settings and set the desired value.
Default
5060
Value Range
1024–65535
Maintenance Console Location
9.5 PBX Configuration—[1-1] Configuration—Slot—Site Property
Feature Manual References
18.1.2 SIP (Session Initiation Protocol) Extension
CWMP (HTTP) Port No. for SIP-MLT