Panasonic KX-NS1000 Pc Programming Manual page 318

Pure ip-pbx
Hide thumbs Also See for KX-NS1000:
Table of Contents

Advertisement

9.11 PBX Configuration—[1-1] Configuration—Slot—V-SIPGW—Port Property
Default
Current status
Value Range
INS: The port is in service.
OUS: The port is out of service.
Fault: The port is not communicating with the network.
Maintenance Console Location
9.11 PBX Configuration—[1-1] Configuration—Slot—V-SIPGW—Port Property
IP Codec Priority—1st, 2nd, 3rd
Specifies the priority of the codecs to be used. None is only available for 2nd and 3rd priorities.
Default
1st: G.711A
2nd: G.711Mu
3rd: G.729A
Value Range
G.711A, G.711Mu, G.729A, None
Maintenance Console Location
9.11 PBX Configuration—[1-1] Configuration—Slot—V-SIPGW—Port Property
Packet Sampling Time (G.711A)
Specifies the time interval between measurements (samples) of sound data during a conversation. The smaller
this number, the higher the quality of the transmitted sound.
Default
20 ms
Value Range
20 ms, 30 ms, 40 ms, 50 ms, 60 ms
Maintenance Console Location
9.11 PBX Configuration—[1-1] Configuration—Slot—V-SIPGW—Port Property
Packet Sampling Time (G.711Mu)
Specifies the time interval between measurements (samples) of sound data during a conversation. The smaller
this number, the higher the quality of the transmitted sound.
Default
20 ms